Power Supply | 220-240V, 50Hz |
---|---|
Refrigerant | R32 |
Indoor Unit Weight | 9 kg |
Cooling Capacity | 12000 BTU/h |
Noise Level (Indoor Unit) | 22-41 dB(A) |
Details on high seasonal efficiency and compact design of outdoor units, highlighting energy-saving performance.
Explains installation patterns supported by branch box connection, including large capacity and long piping design.
Covers branch box mounting, common main pipe diameter, outdoor unit lightening, and 4-way piping connection.
Describes wired, wireless, and central remote controllers, including system configuration and address setting.
Flowchart illustrating the steps for selecting indoor units, branch boxes, separation tubes, and controllers.
Details the available outdoor and indoor units, including model codes, capacities, and types.
Provides procedures and examples for selecting indoor and outdoor units based on heat load and capacity.
Presents cooling and heating capacity tables for the outdoor unit (AOG45LBT8) under various conditions.
Explains compensation coefficients for pipe length and frosting/defrosting operations.
Provides cooling and heating capacity tables for various indoor unit types like Compact Cassette and Slim Duct.
Detailed specifications for the outdoor unit (AOG45LBT8) and branch boxes (UTP-PY03A, UTP-PY02A).
Provides detailed dimensional drawings for the outdoor unit (AOG45LBT8) and branch boxes.
Guidelines for outdoor unit and branch box installation space, including single/multiple unit setups.
Diagram illustrating the refrigerant circuit with outdoor unit, branch boxes, and indoor units.
Provides wiring diagrams for the outdoor unit and branch boxes, showing connections and components.
Specifies the operable temperature and humidity ranges for cooling and heating modes.
Graphs showing noise level curves for the outdoor unit (AOG45LBT8) in cooling and heating modes.
Details electrical specifications for outdoor units and branch boxes, including power, current, and wiring.
Lists safety devices such as fuses, protectors, and pressure settings for outdoor units and branch boxes.
Highlights key features of indoor units, including fan design, maintenance, compact design, and quiet operation.
Provides detailed specifications for Compact Cassette indoor units, including airflow, sound pressure, and dimensions.
Details electrical specifications for various indoor unit types, including power supply, MCA, and FLA.
Provides dimensional drawings for Compact Cassette indoor units, showing installation details and pipe connections.
Illustrates wiring diagrams for Compact Cassette indoor units, showing connections to PCB and remote controllers.
Presents airflow and temperature distribution charts for Compact Cassette indoor units under various conditions.
Shows fan performance curves for Slim Duct indoor units, illustrating static pressure vs. airflow.
Tabulated airflow data (m³/h and CFM) for various indoor unit types and fan speeds.
Graphs showing noise level curves for Compact Cassette indoor units in cooling and heating modes.
Lists safety devices like PCB fuses, fan motor protectors, and thermal fuses for different indoor unit types.
Overview of available controllers: Central, Wired, Simple, Wireless Remote Controllers, and IR Receiver Unit.
Visual presentation of Central, Wired, Simple, Wireless Remote Controllers, and IR Receiver Unit.
Illustrates system diagrams for 1 and 2 remote controller configurations, including wiring and controller combinations.
Details installation procedures for remote controllers, including connection patterns and cable modifications.
Explains how to set functions for outdoor units, including switch positions and mode selection.
Provides guidelines for system design, including indoor unit type and applicable control methods.
Procedure for setting the custom code of wireless remote controllers to match indoor units.
Details the functions and button operations of various remote controllers like AR-RAH2E and AR-REB1E.
Provides a system outline diagram showing outdoor unit, branch boxes, indoor units, and their connections.
Details connectable units within one refrigerant system and prohibits certain combinations.
Covers outdoor unit installation, pipe connection, separation tube, and heat insulation procedures.
Guidelines for electrical wiring, power supply cable wiring, transmission lines, and controller cable wiring.
Instructions for setting functions on outdoor units using push buttons and 7-segment displays.
Details the procedure for performing a check run, including precautions and error checking.
Describes external input modes (Low Noise, Priority, Peak Cut, Stop) and output signals (Error, Compressor).
Provides guidelines for drain connection for outdoor and indoor units, including precautions.
Lists standard accessories supplied with outdoor units for installation purposes.
Instructions for installing optional parts like Fresh Air Intake Kit and Auto Louver Grille Kit.
Provides safety precautions regarding refrigerant leakage and concentration limits for R410A systems.
General precautions for indoor and outdoor unit installation, including prohibited locations and specific conditions.
Details specifications and dimensions for the separation tube (UTP-SX248A).
Presents branch box types (3 and 2 branches) with dimensions and pipe diameters.
Lists available controllers (Central, Wired, Wireless, Simple) and their applicable indoor unit types.
Provides a lineup of other optional parts like grilles, filters, and communication kits.