Heating mode
F zone
E zone
D zone
C zone
B zone
A zone
66.2°F
(19°C)
32.0°F
(0°C)
5.0°F
(-15°C)
-13.0°F
(-25°C)
41.0°F
(5°C)
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOUH09LPAS1
A zone 43 rps
B zone 43 rps
C zone 30 rps
D zone 18 rps
E zone 16 rps
F zone 16 rps
AOUH12LPAS1
A zone 37 rps
B zone 37 rps
C zone 36 rps
D zone 15 rps
E zone 15 rps
F zone 1 rps
1-5. Limitation of compressor rotation number by outdoor temperature - (04-7) - 1. Rotation number control of compressor