3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Fan speed
Indoor fan speed is defined as below.
Operation mode Fan mode
Speed (rpm)
ASUH09LPAS ASUH12LPAS
Heating
POWERFUL 1,230 1,290
HIGH 1,160 1,220
MED+ 1,070 1,140
MED 980 1,060
LOW 800 900
QUIET 620 630
Cool air prevention 550 550
S-LOW 400 470
Cooling/Fan
POWERFUL 1,170 1,290
HIGH 1,100 1,220
MED 920 1,000
LOW 750 810
QUIET 550 550
Soft quiet
470*
1
490*
1
S-LOW
400*
2
470*
2
Dry
X zone: 550
J zone: 550
X zone: 550
J zone: 550
*1: Fan mode only
*2: Cooling mode only
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-10) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS