EasyManua.ls Logo

Fujitsu AU*54LUAS - Outdoor Unit

Fujitsu AU*54LUAS
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03-02
Ø15.88mm(5/8")
Ø9.52mm(3/8")
MODEL : AU*30/ 36LUAS / AO*30/ 36LMAWL
Outdoor Unit Indoor Unit
CONDENSER
HIGH PRESSURE
SWITCH
PRESSURE
CHECK VALVE
THO
THO
THC
THPO
THD
THR
THR
THPI
THPI
THD
THC
THPO
COMPRESSOR
ACCUMULATOR
EXPANSION
VALVE
STRAINERSTRAINER
4-Way
valve
THERMISTOR(DISCHARGE TEMP.)
THERMISTOR(ROOM TEMP.)
THERMISTOR(PIPE TEMP.)
THERMISTOR(OUTDOOR TEMP.)
THERMISTOR(PIPE TEMP.)
THERMISTOR(COMP TOP TEMP.)
Refrigerant Pipe
Refrigerant Pipe
COOL
HEAT
EVAPOLATOR
Charging Valve
Charging Valve

Table of Contents

Related product manuals