Check point 4. Check serial signal (Reverse transfer signal)
Check serial signal (Reverse transfer signal)
RED
WHITE
BLACK
+
-
3
2
1
• Check if indicated value swings between AC 90 V and AC 270 V at the outdoor unit terminal 1
—3.
• If it is abnormal, check the parts below.
– Outdoor unit fan motor in "Service parts information" on page 03-83
– Active filter module in "Service parts information"
• If outdoor fan motor is abnormal, replace outdoor unit fan motor and main PCB.
• If active filter module is abnormal, replace it.
• If the checked parts are normal, replace the main PCB.
↓
End
Check point 1-2. Check external cause such as noise
• Check the complete insulation of the grounding.
• Check if there is any equipment that causes harmonic wave near the power cable (Neon light
bulb or any electronic equipment which causes harmonic wave).
↓
End
2-1. E: 11. Serial communication error (Serial reverse transfer error) (Outdoor unit) - (03-15) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu AUXG07KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG07KVLA and is the answer not in the manual?

Fujitsu AUXG07KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG07KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals