EasyManuals Logo

Fujitsu AUXG07KVLA Service Manual

Fujitsu AUXG07KVLA
471 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #325 background imageLoading...
Page #325 background image
¢ Wall mounted type (For KGTB and KGTE)
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOHG30KBTA4
AOHG36KBTA5
10 130
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASHG07KGTB
ASHG09KGTB
A zone 102 74 63 54
ASHG12KGTB
ASHG14KGTB
B zone 102 87 74 63
ASHG07KGTE
ASHG09KGTE
C zone 130 111 94 80
ASHG12KGTE
ASHG14KGTE
D zone 130 130 130 130
1-1. Cooling operation - (04-5) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AUXG07KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG07KVLA and is the answer not in the manual?

Fujitsu AUXG07KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG07KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals