¢ Wall mounted type (For KETA and KETE)
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOHG30KBTA4
AOHG36KBTA5
10 130
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
Model name
Outdoor
temperature zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASHG07KETA
ASHG07KETA-B
ASHG09KETA
ASHG09KETA-B
A zone 102 74 63 54
ASHG12KETA
ASHG12KETA-B
ASHG14KETA
ASHG14KETA-B
B zone 102 87 74 63
ASHG07KETE
ASHG07KETE-B
ASHG09KETE
ASHG09KETE-B
C zone 130 111 94 80
ASHG12KETE
ASHG12KETE-B
ASHG14KETE
ASHG14KETE-B
D zone 130 130 130 130
1-1. Cooling operation - (04-7) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS