¢ Wall mounted type (For KGTB and KGTE)
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOHG30KBTA4
AOHG36KBTA5
10 130
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASHG07KGTB
ASHG09KGTB
A zone 102 74 63 54
ASHG12KGTB
ASHG14KGTB
B zone 102 87 74 63
ASHG07KGTE
ASHG09KGTE
C zone 130 111 94 80
ASHG12KGTE
ASHG14KGTE
D zone 130 130 130 130