EasyManua.ls Logo

Fujitsu AUXG14KVLA - Page 334

Fujitsu AUXG14KVLA
471 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
¢ Wall mounted type (For KETA and KETE)
Rotation number range of compressor
Unit: rps
Model name Outdoor temperature zone Operating rotation number
ASHG07KETA
ASHG07KETA-B
ASHG09KETA
ASHG09KETA-B
ASHG12KETA
ASHG12KETA-B
X zone 54
ASHG14KETA
ASHG14KETA-B
ASHG07KETE
ASHG07KETE-B
ASHG09KETE
J zone 54
ASHG09KETE-B
ASHG12KETE
ASHG12KETE-B
ASHG14KETE
ASHG14KETE-B
Y zone 0
Compressor control based on room temperature
Ts+0.5°C
Ts -1.5°C
Ts-0.5°C
Ts+1.5°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature
1-3. Dry operation - (04-14) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AUXG14KVLA

Related product manuals