Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
Model name
Outdoor
temperature zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASHG07KMCE
A zone 84 49 36 24
B zone 84 49 36 24
C zone 84 49 36 24
D zone 60 44 34 22
E zone 60 44 34 22
F zone 60 44 34 22
ASHG09KMCE
ASHG12KMCE
A zone 90 52 36 24
B zone 90 52 36 24
C zone 90 52 36 24
D zone 64 46 34 22
E zone 64 46 34 22
F zone 64 46 34 22
ASHG14KMCE
A zone 89 44 34 22
B zone 89 44 34 22
C zone 89 44 34 22
D zone 62 40 32 20
E zone 62 40 32 20
F zone 62 40 32 20
1-1. Cooling operation - (04-2) - 1. Rotation number control of compressor