Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-25°C
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOHG07KMCC
AOHG09KMCC
AOHG12KMCC
A zone 43 rps
B zone 43 rps
C zone 30 rps
D zone 18 rps
E zone 16 rps
F zone 16 rps
AOHG14KMCC
A zone 37 rps
B zone 37 rps
C zone 36 rps
D zone 15 rps
E zone 1 rps
F zone 1 rps
1-5. Limitation of compressor rotation number by outdoor temperature - (04-7) - 1. Rotation number control of compressor