11. IMPORTANT
According to the chapters of norm IEC 60364:
1: Install protector against overvoltage on the power supply
2: Sensor cables and signal cables of the computer may be joined, but not in the same electric
conduit through which the electric input and the activation of the loads run
3: Install transient suppressors (RC filters) parallel to the loads as to increase the product life of
the relays.
4: The withdrawal or substitution of the adhesive panel frontal as well as alterations in the
electronic circuit on the part of the user implies in the cancellation of guarantee.
Schematic for the connection of suppressors
to contactors
Supressor
A1
A2
A1 and A2 are the
contactor coils.
Schematic for the connection of suppressors
to direct activation loads
Load
Supressor
For direct activation the maximum
specified current should be taken
into consideration.