4
18
bintec User’s Guide System
Submenu Schedule & Monitor
Table 4-2: Fields in KEEPALIVE MONITORING interfaces menu
4.2 Submenu Event Scheduler
(Time & SNMP)
Your gateway is equipped with an event scheduler, which makes it possi-
ble to modify existing MIB variables as soon as a certain event (e.g. time-
dependent) occurs.
In general, any event in the MIB can be defined as the trigger.
FirstIfIndex Defines the first interface of an interface range
in the gateway, for which the action (
down or
up) defined under DOWNACTION is to be exe-
cuted.
Possible values: 100 .. 65536
Default value: 10001
Interfaces with indices from 10001 to 14999 are
provided for dialup connections to WAN part
-
ners. You can find the indices of the interfaces
with, for example, the command
ifstat.
Range Defines the range of interfaces in the gateway,
for which the action defined under
ACTION is to
be executed.
If you set FIRSTIFINDEX = 10001 and RANGE = 0,
only the interface with the index
10001 is
affected.
If you set FIRSTIFINDEX = 10001 and RANGE =
4999 (default value), the interfaces with the
indices
10001 to 14999 are affected.
Field Description