FACT12LA-PS/FACT12LA-BL
FACT12SA-PS/FACT12SA-BL
(Sold Separately)
TM
Rooftop Air Conditioner
Instruction Manual
Model:
FACR13SA-PS/FACR13SA-BL
FACR14SA-PS/FACR14SA-BL
FACR15SA-PS/FACR15SA-BL

Questions and Answers

  • H
    Hunter AlexanderAug 6, 2025
    What to do if Furrion FACR13SA-PS is not cool enough?
    • A
      Amy HolmesAug 6, 2025
      If your Furrion Air Conditioner isn't cooling sufficiently, there could be several reasons. Ensure the unit is set to cooling and that the set temperature isn't too high; try selecting a lower temperature. Check for blocked air intake grilles and clear any obstructions. For refrigerant leakage, a defective blower, or damaged evaporator/condenser fans, contact an authorized service agent or Furrion.
  • O
    oballAug 12, 2025
    What to do if Furrion FACR13SA-PS Air Conditioner does not switch on?
    • J
      Jeremy HartAug 12, 2025
      If your Furrion Air Conditioner fails to switch on, start by checking the power supply to ensure it's connected. Also, inspect the electrical fuse of the power supply. If the voltage is too low, contact an authorized service agent or Furrion.
  • J
    John MartinAug 20, 2025
    What to do if water enters the vehicle from Furrion Air Conditioner?
    • C
      charles79Aug 20, 2025
      If water is entering your vehicle from the Furrion Air Conditioner, the condensation water drainage openings may be clogged. Clean these drainage openings. If the seals are damaged, contact an authorized service agent or Furrion.
  • C
    Christopher AdamsAug 27, 2025
    Why Furrion Rooftop Air Conditioner Abnormal shutdown?
    • A
      Amanda FigueroaAug 28, 2025
      A Furrion Rooftop Air Conditioner might shut down abnormally if the freeze sensor has tripped, which can occur if the outside temperature is too low or all air nozzles are closed.

Summary

Important Safety Instructions

Handling the Device

Safety guidelines for installation, repair, and use of electrical devices.

Handling Electrical Cables

Guidelines for safe connection and routing of electrical power supply cables.

Before Installing

Whats in the Box

Lists components included with the rooftop air conditioner and air distribution box.

Choosing Proper Location for the Air Conditioner

Guidance on selecting the optimal mounting location on the RV roof.

Roof Preparation

Instructions for preparing the roof opening for the air conditioner installation.

Air Distribution Duct Sizing and Design

Requirements and considerations for designing the air distribution ductwork system.

Air Distribution System Installation

Steps for installing the air distribution system components and ensuring proper airflow.

Laying the Connecting Cables

Procedure for routing and connecting the electrical power supply and control cables.

Installation

Installing the Rooftop Unit

Steps for physically mounting the rooftop air conditioner unit onto the prepared roof opening.

Installing the Wall Thermostat

Guidance on installing the selected wall thermostat model.

Installing the Air Distribution Box

Detailed instructions for fitting the air distribution box and associated components.

Cleaning and Maintenance

To Clean the Filter

Procedure for cleaning the air conditioner filters to maintain performance.

To Replace the Filter

Guidance on when and how to replace the air conditioner filters.

Troubleshooting

Specifications

Wiring Diagram

Multi Zone Wiring Diagram

Furrion FACR13SA-PS Specifications

General IconGeneral
BrandFurrion
ModelFACR13SA-PS
CategoryAir Conditioner
LanguageEnglish

Related product manuals