FITELNINJA NJ001
Quick Reference guide
FTS-B495
Issue 3
Turn on power.
< Fiber Preparation >
Stripping the fiber coating
S210 Fiber Stripper
Fiber Cleaning
Fiber Cleaving
Lint-free
tissue with
ethanol
Hold the fiber tightly.
Then move S210
into the direction
indicated by the
arrow mark.
Safety Instructions
Before operating this product, please read the user’s manual of safety
instructions. The safety instructions are to help you use this product in a
safe and correct way, and to prevent danger or injury to yourself or others.
Single Fiber Adapter
Splicing Procedure
End.
Remove the fiber.
Press key.
Place fiber to heater.
Slide protection sleeve over
spiced point.
Remove spliced fiber.
Press key.
Set fibers to the splicer.
Prepare the fibers.
Insert protection sleeve.
Perform Arc Check.
Please see “Arc Check” for
details.
Select applicable program.
Setting the fiber on the splicer
The edge of the fiber coating should
match with the edge of the tight holder.
Edge of the coating
Press the lever.
Question and Answer IconNeed help?

Do you have a question about the Furukawa electric FITELNINJA NJ001 and is the answer not in the manual?

Furukawa electric FITELNINJA NJ001 Specifications

General IconGeneral
Product NameFITELNINJA NJ001
ManufacturerFurukawa Electric
CategoryIndustrial Electrical
TypeFusion Splicer
Fiber AlignmentCore Alignment
Typical Splice Loss (SM)0.02 dB
Typical Splice Loss (MM)0.01 dB
Typical Splice Loss (DS)0.04 dB
Typical Splice Loss (NZDS)0.04 dB
Operating Condition (Wind)15 m/s
Dimensions128W x 154D x 130H mm
Applicable FibersSM, MM, DS, NZDS
Return Loss≥60 dB
Applicable Fiber/Cable Diameter (Cladding)125 μm
Applicable Fiber/Cable Diameter (Coating)250 to 900 µm
Protection Sleeve Length60 mm, 40 mm
Monitor4.3-inch color LCD monitor
Data OutputUSB 2.0
Power SupplyAC 100-240V, DC 11-17V
Operating Condition (Altitude)0 - 5, 000 m
Operating Temperature-10 to 50 °C
Operating Condition (Humidity)0 to 95% RH (non-condensing)
Storage Temperature-40 to +60 degrees Celsius
Storage Condition (Humidity)0 to 95% RH (non-condensing)

Summary

Safety Instructions

Splicing Procedure

Fiber Preparation

Procedure for stripping fiber coating and preparing fibers for splicing.

Fiber Cleaning

Instructions for cleaning fiber using lint-free tissue and ethanol.

Fiber Cleaving

Steps for cleaving fibers using the single fiber adapter.

Setting the fiber on the splicer

How to correctly position fibers on the splicer for optimal results.

Arc Check

To ensure optimal splicing results

Operation Keys

Power Key

Turns the power on and off.