4. INSTALLATION
4-7
Fabricate these cables as below to connect to the receiver unit.
DPYC-1.5 (For external alarm)
100 mm
5 mm
Scrape the paint off the cable
where the cable contacts the cable clamp.
Vinyl sheath
Soldering
Vinyl wire
25 mm
TTYCS-1Q (For Navigator or INS)
100 mm
5 mm
Scrape the paint off the cable
where the cable contacts the cable clamp.
Vinyl sheath
Soldering
Shield
Vinyl wire
25 mm
DPYC-2.5 (For ship’s battery)
100 mm
5 mm
Scrape the paint off the cable
where the cable contacts the cable clamp.
Vinyl sheath
Crimp-on lug
(M4, local supply)
25 mm
How to use J402 and 403 connector
1. Insert the terminal opener (attached in the receiver unit) into the connector.
2. Insert a wire in terminal while pressing and holding the terminal opener.
3. Release the terminal opener. Pull wire to confirm that it is connected firmly.
Wire
Terminal opener