92
Linkagemenu
RegisteredsensorSlotNumber
Thisiswhatdisplayswhenno
sensorisregisteredinaslot.
Tappingtheslotandselecting
"-----------"willerasewhateverwas
registeredthere,freeingupthe
slot.
Taptheslottodisplay
sensorswhichcanbeused
forthestartslot.Tapto
registerthesensor.
SensorID:Multipleusageofsensors
ofthesametyperequiresanID
beinput.Tappingthiswillallow
formanualinput,butseethenext
pageabouthowtoperformauto-
registrationviasensorregistration.
Sensor
9DULRXVWHOHPHWU\VHQVRUVVHWWLQJ
This screen registers the telemetry sensors used
with the transmitter. When only one of a certain
type of sensor is used, this setting is unnecessary
and the sensor can be used by simply connecting it
WRWKH6%86SRUWRIWKHWUDQVPLWWHU
:KHQXVLQJRUPRUHRIWKHVDPHNLQGRI
sensor, they must be registered here.
[What is a slot?]
6HUYRVDUHFODVVLILHGE\&+EXWsensors are
classified in units called “slot”. There are slots from
No. 1 to No. 31.
Altitude sensors, GPS sensors and other data
sensor units may use multiple slots.
When using a sensor which uses two or more slots,
the required number of slots is automatically assigned
by setting up a start slot.
:KHQRUPRUHRIWKHVDPHNLQGRIVHQVRUDUHXVHG
the sensors themselves must allocate unused slots and
memorize that slot.
ŏ$VVKRZQLQWKHWDEOHEHORZDQDOWLPHWHUUHTXLUHVFRQWLJXRXVVORWVDQGD*36VHQVRU
UHTXLUHVFRQWLJXRXVVORWV7KH*366%6*VWDUWVORWVDUHDQG
$VVLJQDEOHVORW
$OWLPHWHU*36DQGRWKHUVHQVRUVWKDWGLVSOD\DODUJHDPRXQWRIGDWDUHTXLUHPXOWLSOHVORWV
*Depending on the type of sensor, the slot numbers that can be allocated may be limited.
ŏ7DSWKH>6HQVRU@EXWWRQLQWKH/LQNDJHPHQX
WRFDOOWKHVHWXSVFUHHQVKRZQEHORZ
Sensor
The required
number of slots
The number which can be used as a start slot Selling area
TEMP (SBS-01T/TE) 1 slot 1-31
Global
RPM (SBS01RM/R
O/RB)
1 slot 1-31
Voltage (SBS-01V) 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,
20,21,22,24,25,26,27,28,29,30
Altitude (SBS-01/02A) 3 slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,
24,25,26,27,28,29
Current (SBS-01C) 3 slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,
24,25,26,27,28,29
S.BUS Servo sennsor
SBS-01S)
6 slots
1,2,8,9,10,16,17,18,
24,25,26
GPS(SBS-01/02G) 8 slots 8,16,24
TEMP125-F1713 1 slot 1-31
Europe
VARIO-F1712 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,
20,21,22,24,25,26,27,28,29,30
VARIO-F1672 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,
20,21,22,24,25,26,27,28,29,30
CURR-F1678 3 slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,
24,25,26,27,28,29
GPS-F1675 8 slots 8,16,24
Kontronik ESC 8 slots 8,16,24
Castle TL0 8 slots 8,16,24
JetCat V10 14 slots
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,
18
PowerBox 16 slots 8,16