Malfunctions and troubleshooting
The machine starts badly or cannot be started at all:
Check whether the spark plug generates a spark. Unscrew the spark plug. Insert
the spark plug back into the spark plug connector and ensure that the spark plug
is grounded. Check the voltage and see if the spark plug has an ignition spark. Be
careful with the starter motor; do not touch the metal on the spark plug for
protection to prevent electric shock.
Fig. 15
ENGINE
Please note that the following maintenance
intervals apply only under normal operating
conditions. Longer working hours or extreme
working conditions (too dusty working area,
etc.) shorten the recommended intervals
accordingly.
Before use
After use
or every
day
After each filling
monthly
annually
When problems
occur
If damaged
On-demand
Complete device
Visual inspection
(condition, fuel, and other
leaks)
x
x
Cleaning
x
Control handle
Check operation
x
x