LUXOR
15 V tap
15 V
Common
Watts shown are per 12 AWG (2.05 mm) cable. Install
additional cable runs as needed to complete the project.
To increase the maximum wattage, run 8 AWG (3.26 mm)
or double 12 AWG (2.05 mm) to the rst xture in the
zone. Use a digital voltmeter to ne-tune circuits.
Out There Zone:
120 to 160'
(36.6 to 54.9 m)
LED 110 W max.
9
Installing the Luxor Transformer
Summary
For maximum light output and LED life, each luminaire should be
provided with 10 to 15 VAC (ZD) and 11 to 15 VAC (ZDC).
Cable Stats
Low-voltage lighting systems are typically installed using
stranded, direct-burial-rated cable. The most common cable
used is 12/2 AWG (2.05 mm) stranded cable. The size of cable
used in wiring the lighting system will be determined by the
wattage load and length of cable run from the transformer to the
lighting xtures.
It is very important to note that all low-voltage cable has a
maximum rating. Overloading cable can create a dangerous
safety hazard, so be sure to choose the right cable size for
your lighting system.
Figure 5: Wiring example