3E4721 Gallagher B60 Portable Energizer User Manual
TIPS & TROUBLESHOOTING
Symptom Problem Solu on
Status LED is
solid red
Energizer has stopped pulsing due
to ba ery voltage falling less than
11 V. (This protects the ba ery
from permanent damage.)
Replace fl at ba ery with a
fully charged one
No voltage on
fence
• Fence shorted
• Fence disconnected from
energizer.
• Energizer may have been
damaged by lightning
Check energizer isn’t
faulty;
- disconnect from fence
and earth
- measure across fence
and earth terminals
with a Gallagher Fence
Volt Meter
- if less than 5 kV return
energizer for service
- if more than 5 kV the
fault is with the fence
or earth system.