In case of installing multiple units in lateral connection per row.
7.4.2 In case of multiple-row installation (for roof top use, etc.)
500mm
500mm
B2
A
B1
C
H
Unit
A(mm) B1(mm) B2(mm) C(mm)
4~6kW
8~16kW
≥2500
≥1500
≥1000
≥300
≥600
≥3000
© All rights reserved - Galmet Sp. z o.o. Sp. K. Installation and operation manual - air-water heat pump Prima 101