CADIAX compact
GAMMA
Medizinisch-wissenschaftliche
Fortbildungs-GmbH
C
0483
A Practical Method for
TMJ Registration
Operating Instructions

Table of Contents

Questions and Answers

  • G
    gallegoschristopherAug 15, 2025
    What to do if Medical Equipment by Gamma indicates no stylus-flag contact after mounting?
    • D
      Darrell PachecoAug 15, 2025
      If the Medical Equipment by Gamma indicates no stylus-flag contact after mounting, several issues could be the cause. First, ensure both styli and flags are securely plugged into the CADIAX device. Verify that the right and left measuring sensors are not interchanged and are correctly inserted. Remount the face bow, ensuring styli remain on the flag's black measuring surface during movements. If the flag is soiled, clean it according to the instructions to ensure electrical contact. If the issue persists, a stylus, flag, or the CADIAX device itself may be defective, requiring service.
  • J
    Justin TaylorAug 18, 2025
    How to fix Medical Equipment by Gamma not detected with unlit LED?
    • E
      Eddie HernandezAug 18, 2025
      If the Medical Equipment by Gamma device is not detected by the recording software and the green LED is unlit, first, ensure the device is properly connected to your computer using a USB port. If the connection is defective, try using another USB port or a different USB cable. If the problem persists, the CADIAX device may be defective and require service.
  • M
    micheal59Aug 21, 2025
    Why does Medical Equipment by Gamma show strong artifacts in recorded curves?
    • M
      michaelhobbsAug 22, 2025
      If the Medical Equipment by Gamma's recorded curves show strong artifacts, it could be due to several reasons. Ensure the measuring flag is clean, as soiling can disrupt electrical contact. Also, verify that the stylus is correctly positioned on the flag's measuring area by remounting the face bow. The issue might also be caused by the "sliding chair effect"; applying a minimal amount of medical petroleum jelly can help, but remember to clean the flag afterward. If these steps don't resolve the problem, the stylus, flag, or CADIAX device may be defective.
  • M
    Matthew YangAug 25, 2025
    What to do if Medical Equipment by Gamma is not detected but LED is lit?
    • B
      bjacobsonAug 26, 2025
      If the Medical Equipment by Gamma device is not detected by the recording software, but the green LED is lit, try using another USB port or cable to rule out a defective connection. If that doesn't work, the driver software may not be installed correctly. Disconnect the CADIAX device, start the software setup routine, and perform a repair. Restart your computer, reconnect the device, and allow the operating system to finish the configuration before starting the recording software. Alternatively, if your computer is connected to the internet, you can allow Windows Update to install the drivers automatically. If the issue persists, it could be due to a software-related issue or a defective CADIAX device.
  • L
    Laura JacobsAug 28, 2025
    How to adjust Medical Equipment by Gamma styli within measuring surface?
    • J
      Jason SextonAug 28, 2025
      If, after mounting the Medical Equipment by Gamma, the styli are outside the black measuring surface areas, repeat the writing bow adjustment procedure. Ensure the patient's lower jaw is in the reference position and closed in a centric position. Also, check that the writing bow's holding clamps are firmly tightened on both the clutch shaft and side arms to prevent displacement. Finally, make sure the writing bow is adjusted without tension, especially when removing the axis locators.
  • D
    Dennis OrtizAug 31, 2025
    What does blinking LED on Medical Equipment by Gamma mean?
    • M
      Michelle GatesAug 31, 2025
      If the Medical Equipment by Gamma's green LED blinks slowly and the recording software indicates a hardware defect, the CADIAX device may be defective.
  • C
    Christopher AdkinsSep 3, 2025
    How to correct backwards curves on Medical Equipment by Gamma?
    • C
      Christian SchneiderSep 4, 2025
      If the recorded curves of the Medical Equipment by Gamma go "backwards" instead of protrusive, it means that the right and left measuring sensors are erroneously interchanged. To fix this, insert the plugs correctly.
  • M
    Matthew PierceSep 7, 2025
    Why are Medical Equipment by Gamma recorded curves too short?
    • J
      jenkinsloganSep 7, 2025
      If the recorded curves of the Medical Equipment by Gamma are too short on one side, it could be due to a soiled measuring flag; clean it to ensure continuous electrical contact. Alternatively, the stylus may be outside the measuring area, requiring you to remount the face bow. Also, verify that the right or left measuring sensors are correctly connected to the device. If the problem persists, the stylus, flag, or CADIAX device might be defective.
  • J
    Jessica JonesSep 12, 2025
    How to fix Medical Equipment by Gamma curves not starting at origin?
    • L
      Lori ChoiSep 12, 2025
      If the recorded curves from the Medical Equipment by Gamma do not begin in the coordinate origin, it's likely that the stylus position has changed between setting the reference position and starting the recording. Repeat setting the reference position, and if necessary, repeat this procedure before each recording.

Summary

Introduction

Explanation of used symbols on packaging and device

Explains symbols used on the product and in the operating instructions.

Important safety considerations

Crucial safety information for operating the device and ensuring user safety.

Intended purpose

Describes the CADIAX system's designed function for TMJ movement registration and articulator setup.

About this manual

Provides context and prerequisites for understanding the manual's content.

Symbols and notations

Details special symbols and notations used throughout the manual for clarity and emphasis.

User interface terminology

Defines key terms and parts of the software's user interface for easier navigation.

Scope of delivery

Lists the items included in the CADIAX system package and required accessories.

System requirements

Specifies the minimum computer hardware and software needed to operate the CADIAX system.

Preparing to operate the CADIAX device

Installing the software

Step-by-step guide to install the CADIAX software and necessary drivers on the computer.

Starting and activating the software

Instructions for launching the CADIAX software and completing the activation process.

Setting the face bow

Details how to select and configure the appropriate face bow type for recordings.

Setting the articulator

Explains how to select and set the correct articulator type within the software.

Recording TMJ movement

Posture of the patient

Guidelines for positioning the patient correctly to ensure accurate TMJ movement recordings.

Instructing the patient

How to explain and practice jaw movements with the patient before recording.

Preparations

Steps and materials required before starting the TMJ registration process.

Mounting the anatomic facebow

Detailed instructions for preparing and mounting the anatomic face bow onto the patient.

Mounting the kinematic facebow

Detailed instructions for preparing and mounting the kinematic face bow onto the patient.

Setting up the CADIAX system

Connecting the CADIAX device, foot switch, and sensors to the computer and system.

Face bow parameter input

Inputting face bow parameters into the software for accurate recording recalculation.

Setting the reference position

Establishing the zero point for TMJ movement recordings by guiding the patient to a reference position.

Recording joint movements

Procedures for initiating and performing recordings of jaw movements using the CADIAX system.

Finishing the registration

Steps to complete the TMJ registration, save data, and dismantle the system.

Data evaluation

Retrieval and analysis of recordings

How to open, view, and analyze recorded TMJ movement data and curves.

Calculating articulator settings

Process for calculating and obtaining optimal settings for articulators based on recorded data.

Data printout

Instructions for generating and customizing printed reports of patient data and analysis.

Mounting the articulator

Troubleshooting

Background information

The reference coordinate system

Explanation of the axis-orbital coordinate system used for CADIAX data and articulator transfer.

Exact and anatomic hinge axis

Differentiates between exact (kinematic) and anatomic (arbitrary) hinge axis recording methods.

Immediate side shift (ISS)

Explains the concepts of immediate side shift (ISS) and progressive side shift (PSS) in articulator systems.

Specifications

Technical data

Lists the technical specifications, including ADC resolution, accuracy, and power requirements.

Cleaning

Provides instructions and precautions for cleaning the CADIAX device and its components.

Recurrent tests

Recommends periodic testing for the CADIAX device's measurement function and security.

Operating conditions

Specifies the recommended environmental conditions for operating the CADIAX device.

Storage and transport

Guidelines for storing and transporting the CADIAX system and its accessories safely.

Disposal

Instructions for correctly disposing of the CADIAX device and its components after their product life.

Gamma CADIAX compact Series Specifications

General IconGeneral
BrandGamma
ModelCADIAX compact Series
CategoryMedical Equipment
LanguageEnglish