III. Technical Specifications
Model GP00
GP01
GP02
GP03
GP04
GP05
GP06
GP07
Performance Condition: Air 26
, Water 26
Heating capacity
KW
3.6 5 7 10 13 17 25 26
C.O.P.
5.2 5.3 6.3 6.2 6.3 6.2 6.4 6.5
Performance Condition: Air 15
, Water 26
Heating capacity
KW
2.7 3.7 5 7 9 12 16.5 17
C.O.P.
4.1 4.3 4.5 4.4 4.5 4.5 4.5 4.7
Advised Water Flux
m³/h
2.5 3 3-4 4-6 5-7 6.5-8.5
8-10 8-10
Power supply 220-240V/1Ph/50Hz
380-415V/3
Ph/50Hz
Rated power Kw
0.66 0.86 1.11 1.59 2 2.67 3.67 3.62
Rated current A 3 3.9 5.0 7.2 9.1 12.1 16.7 5.5
Water pipe in-out
spec mm
50
Water pipe in-out
spec(For UK) mm
48
Net weight / Gross
weight Kg
31/36 35/40 45/50 52/57 66/70 85/93 127/137
127/137
Notice:
1- This Heat Pump can work well between 0℃~+43 air temperature;
efficiency will not be guaranteed out of this range. Please take into
consideration that the pool heater performances may vary under different
conditions. Consult your Pool specialist.
2- We reserve the right to make improvements periodically without further
notice. For details please refer to the cover-plate on the Heat Pump.