EasyManua.ls Logo

Gardena 1867 - 7. TROUBLESHOOTING; Common Operational Issues; LED Indicator Meanings

Gardena 1867
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8. TECHNICAL DATA
Soil Moisture Sensor
Unit Value (Art. 1867)
Connection cable m 5
Outdoor operating temperature °C 5 – 50
Storage temperature °C – 20 + 60
Batteries required 2 x alkalimanganese (alkaline) batteries type LR6 (AA) (Mignon)
Operating time of the batteries approx. 1 year with alkaline batteries (min. 2000 mAh)
Problem Possible Cause Remedy
Watering is switched on
although soil is damp
Defective or loose sensor cable. v Check the sensor cable and the connections.
Batteries spent / inserted incorrectly /
wrong batteries used.
v Replace the batteries / insert correctly / use alkaline
batteries.
Air is trapped at the sensor tip. v Remove the trapped air (see 3.INITIAL OPERATION
To plant the sensor
).
Watering is not switched on
although soil is dry
Sensor is in a dip in the ground. v Insert the sensor in the correct position
(see 3. INITIAL OPERATION
To select the
correct location
).
Switching point is selected too dry. v Select the switching point “damper”.
LED battery flashes red Batteries of the sensor are flat. v Replace the batteries of the sensor.
LED battery illuminates red Sensor is defective. v Contact the GARDENA Service.
NOTE: For any other malfunctions please contact the GARDENA service department. Repairs must only be done by GARDENA service
departments or specialist dealers approved by GARDENA.
17