Problem Possible Cause Remedy
Display shows
when button / setting
dial is activated
Buttons have been locked.
v Press the
button for 3 seconds.
Manual watering is
not possible using the
button
Low battery is continuously displayed. v Insert a new (alkaline) battery.
Tap is turned off. v Turn the tap on.
Controller is not connected. v Mount the controller on housing.
Minimum pressure of 0.5 bar not
available.
v Ensure a pressure of at least
0.5 bar.
Watering program is
not being undertaken
(no watering)
Program entry / modification during or
just before the start pulse.
v Make program entry / modification
outside the programmed start times.
Valve was opened manually previously. v Avoid possible program overlaps.
Tap is turned off. v Turn the tap on.
Soil moisture or rain sensor registers damp. v If dry, check the setting / location of
the soil moisture / rain sensor.
Controller is not connected. v Mount the controller on housing.
Low battery is continuously displayed. v Insert a new (alkaline) battery.
Minimum pressure of 0.5 bar not
available.
v Ensure a pressure of at least
0.5 bar.
Water Control does
not close
Minimum quantity of water drawn is
less than 20 l/h.
v Connect more drip heads.
Valve soiled. v Flush in the opposite direction to the
normal flow direction.