Operating Gardtec 500
To alleviate any possibility of
error
, always insert 0
(zero)
in front of a user code entry.
0
(zero)
should not be
used as part of a user code.
Function
Action
Result
Display
To Set System
Enter User Code
Exit sounder commences
continuous tone during exit
time
1
st
2
nd
To Unset System
a) Enter premises via entry
route
b) Enter User Code
Entry sounder starts
intermittant tone
Entry sounder s
ilences
-
U
Isolating Zones
(ie night set or garage set)
NB
:-
After
u
nsetting the
system after zone omits
the display will identify the
zones omitted during the
last setting
Enter User Code
followed
by
*
and zone number
.
(for multiple zone omits
enter code
-
* zone no *
zone no etc)
Exit sound starts
continuous tone for
duration of exit time
1
st
2
nd
Changing the User Code
NB:
- R
emember
not to use
a 0 (zero) as part of a code
a) Enter the user code
b) Enter
*9
followed by the
new code
c) Press 0 (zero) to clear
display
a)
Exit sounder starts
b)
Sounder silences
and
display shows the new
code in sequence followed
by U
c)
Panel returns to unset
U
?
?
?
?
U
U
Chime Function
(for
walk
testing detector
s
or identifying area
movement)
To remove chime function
press 0 (zero)
Enter 0 # 6
Movement through any
detector while system is
unset creates a 2 second
tone
U
Sounder Test
Enter 0 # 9
External sounder & strobe
will sound for 10 seconds
follwed by internal sounder
for 10 seconds
U
To Read Event Log
(last 13 events)
Enter 0 # 8
Display
will scroll through
last 13 even
ts of activation
1
2
3
4
5 - - - -
13
?
?
?
?
To Clear Display
If the display scrolls
between U (unset) and any
zone information press 0
(zero) to clear after
investigating cause of
activation)
U
Quick Set Option
Enter 0 # 4
Normal set procedure
MCM Alarms
The
Old Dairy
77
Robinson Road
Rushden
Northamptonshire
NN1
0 0EH
-
0870 749 0263
Fax:
-
0870 749 0264
Email
support@mcmalarms.co.uk
Web:
-
www.mcmalarms.co.uk
U
-
h
-

Other manuals for GARDINER TECHNOLOGY Gardtec 500 series

Question and Answer IconNeed help?

Do you have a question about the GARDINER TECHNOLOGY Gardtec 500 series and is the answer not in the manual?

GARDINER TECHNOLOGY Gardtec 500 series Specifications

General IconGeneral
BrandGARDINER TECHNOLOGY
ModelGardtec 500 series
CategoryPower Supply
LanguageEnglish

Summary

Gardtec 500 Operation

To Set System

Enter User Code to commence exit sounder during exit time.

To Unset System

Enter premises via entry route, then user code to silence entry sounder.

Isolating Zones

Enter user code, *, and zone number for zone isolation.

Changing the User Code

Enter current code, *9, new code, then 0 to clear display.

Chime Function

Enter 0 # 6 for chime; press 0 to remove chime function.

Sounder Test

Enter 0 # 9 for sounder and strobe test.

To Read Event Log

Enter 0 # 8 to view last 13 activation events.

To Clear Display

Press 0 (zero) to clear display after investigating activation cause.

Quick Set Option

Enter 0 # 4 for normal set procedure.

Related product manuals