Questions and Answers

  • R
    Robert BlackAug 15, 2025
    Why is there a loss of hydraulic system power in my Gardner Denver Lifting Systems?
    • W
      wrightzacharyAug 15, 2025
      If your Gardner Denver Lifting Systems experiences a loss of hydraulic system power, first ensure the emergency stop button is disengaged. Next, check that the power take off unit is fully engaged. If the problem persists, the geared power take off unit or the main hydraulic pump may have failed and require testing by replacement. Finally, verify that the relief valve isn't blowing off due to an incorrect pressure setting; if so, reset it to 190 Bar.
  • A
    andrew99Aug 18, 2025
    Why is the hydraulic oil overheating in my Gardner Denver Lifting Systems?
    • K
      Kayla DunnAug 18, 2025
      If the hydraulic oil in your Gardner Denver Lifting Systems is overheating, start by checking the hydraulic oil reservoir contents and replenish if low. If the issue continues, the main hydraulic pump might be worn. Connect a flow meter and pressure gauge to the pressure side of the hydraulic pump - the pump delivers approximately 8 liters/min at 190 Bar – renew if necessary. Also, check if the relief valve is blowing and reset it to 190 Bar if needed.
  • K
    kellyphamAug 21, 2025
    What to do if there is complete electrical failure in Gardner Denver VM 135?
    • P
      Paul NortonAug 21, 2025
      If you're experiencing a complete electrical failure with your Gardner Denver Lifting Systems and there are no indicator lights at the stabilizer control panel, the first thing to check is the main input 40 Amp fuse under the dash. Then, inspect the PTO fuse 10 amp in the control panel (No6), followed by the panel fuse 25 amp in the control panel. Replace any blown fuses and investigate the cause of the failure.
  • E
    Erin HaleAug 25, 2025
    Why do the stabiliser legs creep upwards on my Gardner Denver VM 135 Lifting Systems?
    • K
      Keith McdonaldAug 25, 2025
      If the stabiliser legs of your Gardner Denver Lifting Systems creep upwards while operating the platform, this is likely due to lock valve leakage. Stop operating the platform as soon as possible, stow the stabilizers, and renew the malfunctioning lock valve cartridge. Do not operate the platform until the fault is rectified.
  • R
    Robert KennedyAug 27, 2025
    What to do if platform booms creep downwards on Gardner Denver VM 135 Lifting Systems?
    • G
      Gregory RyanAug 27, 2025
      If the platform booms on your Gardner Denver Lifting Systems creep downwards, it's likely due to lock valve leakage. Stop operating the platform as soon as possible, stow the platform, and renew the malfunctioning lock valve cartridge. Do not operate the platform until the fault is rectified.
  • B
    brandy12Aug 30, 2025
    What to do if stabilizers deploy but there's no boom hydraulic power in Gardner Denver Lifting Systems?
    • B
      Billy Scott IVAug 30, 2025
      If your Gardner Denver Lifting Systems stabilisers can be deployed/stowed but there's no hydraulic power to the boom, the issue could stem from a few potential causes. Start by testing the leg set switch, cables and dump valve solenoid using a multi meter, and renew if necessary.
  • B
    Brandon SchwartzSep 2, 2025
    What causes slew failure with manual slewing only in Gardner Denver VM 135 Lifting Systems?
    • S
      stevenelliottSep 2, 2025
      If your Gardner Denver Lifting Systems experiences slew failure with manual slewing only, inspect all flexible hoses and fittings for hydraulic oil leakage, and replace if necessary. If leakage isn't the issue, the slew motor might have failed and requires testing by replacement.
  • M
    Megan WadeSep 5, 2025
    What does it mean if the slew fault light illuminates on Gardner Denver VM 135 Lifting Systems?
    • T
      Theresa WilsonSep 6, 2025
      If the slew fault light illuminates on your Gardner Denver Lifting Systems, it may be due to a switch being dislodged or faulty. Try resetting the position of the limit switch, or replace it if necessary.
  • C
    Christopher WebbSep 8, 2025
    What causes complete slew failure in Gardner Denver VM 135 Lifting Systems?
    • C
      Cynthia WhiteSep 8, 2025
      If your Gardner Denver Lifting Systems experiences complete slew failure, the internal damage to the slew assembly worm drive may be the cause. In this case, replace the complete assembly.
  • D
    Donna LiuSep 12, 2025
    What causes slew failure with no manual slewing in Gardner Denver Lifting Systems?
    • C
      courtneymoranSep 12, 2025
      If your Gardner Denver Lifting Systems experiences slew failure with no manual slewing, the seized slew motor may be the cause. Test by replacement.

Summary

SAFETY

SPECIFICATION

CONSTRUCTION

SAFETY INTERLOCK

OPERATING INSTRUCTIONS

HYDRAULIC POWER - PTO (Power Take-Off)-(Landrover)

INCLINOMETER

WALK IN BASKET

PLATFORM CAGE CONTROLS

PUSH BUTTON CONTROLS

Ground Control Pendant

OPERATING METHOD

LOAD SENSING SYSTEM

PREPARATION FOR TRAVELLING

EMERGENCY OPERATION

EMERGENCY SLEWING-GDK SLEW WORMDRIVE (EARLY MODELS)

Manual slewing procedure using a hand crank for early models with GDK slew wormdrive.

EMERGENCY SLEWING-IMO SLEW WORMDRIVE

EMERGENCY LOWERING

SAFETY RULES

SAFE WORKING PRACTICE

Essential safety rules covering 'NEVER' and 'ALWAYS' actions for safe operation.

OPERATING NEAR TO POWER LINES

WIND STRENGTH

SERVICE INSTRUCTIONS

HYDRAULIC OIL LEVEL

DRAINING AND RE-FILLING THE HYDRAULIC SYSTEM

Step-by-step guide for draining, cleaning strainers, and refilling the hydraulic system.

CLEAN OIL RESERVOIR

PRIME SYSTEM

HYDRAULIC OIL LEAKAGE

TORQUE CHECKS

PLATFORM INSPECTION AND TESTS

TROUBLE SHOOTING

PARTS ORDERING PROCEDURE

MAJOR HYDRAULIC ITEMS

VM135 HYDRAULIC CIRCUIT

VM135 ELECTRICAL SCHEMATIC

Gardner Denver VM 135 Specifications

General IconGeneral
BrandGardner Denver
ModelVM 135
CategoryLifting Systems
LanguageEnglish