EasyManua.ls Logo

Gas Detection GTD-2000Tx - User Manual

Gas Detection GTD-2000Tx
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GTD-2000Tx
Instruction Manual
Headquarters / Engineering research laboratory :
23 Gunpo Advance d Industry 1-ro(Bugok-dong), Gunpo-si, Gyeonggi-do
Tel +82-31-490-0800 Fax +82-31-490-0801
Yeongnam business office / Plant :
55 Gonghangap-gil 85beon-gil, Gangseogu, Busan Metropolitan City
Tel +51-973-8518 Fax +51-973-8519
E-mail : info@gastron.com
www.gastron.com
Read in detail for correct use.
GTD-2000Tx
Instruction Manual
Headquarters / Engineering research laboratory :
23 Gunpo Advance d Industry 1-ro(Bugok-dong), Gunpo-si, Gyeonggi-do
Tel +82-31-490-0800 Fax +82-31-490-0801
Yeongnam business office / Plant :
55 Gonghangap-gil 85beon-gil, Gangseogu, Busan Metropolitan City
Tel +51-973-8518 Fax +51-973-8519
E-mail : info@gastron.com
www.gastron.com
Read in detail for correct use.

Questions and Answers

Summary

Overview of GTD-2000 Tx Gas Detector

GTD-2000 Tx Gas Detector Structure

GTD-2000 Tx Gas Detector Specifications

Basic Specifications

Lists key technical specifications of the gas detector, including measuring type, range, accuracy, and approvals.

Mechanical Specifications

Details physical dimensions, weight, mounting type, connection sizes, and body material.

Electrical Specifications

Outlines electrical input voltage, wattage, output current, wiring requirements, and EMC protection.

Environmental Specifications

Specifies operating temperature, storage temperature, humidity, pressure range, and air velocity.

GTD-2000 Tx Components Identification

Component Descriptions

Identifies and describes the main physical components of the gas detector, including housing and PCBs.

GTD-2000 Tx Installation Guide

Housing Cover Detachment

Explains how to safely remove the detector's housing cover for access to internal components.

Main PCB Configuration Layout

Shows the layout of the main Printed Circuit Board (PCB) and identifies its key connection points.

Terminal Configuration

Details how to connect power and signal cables to the terminal block on the main PCB.

Wiring for 4~20 mA Source Operation

Provides specific wiring instructions for the 4-20mA source operation mode.

Wiring for 4~20 mA Sink Operation

Provides specific wiring instructions for the 4-20mA sink operation mode.

Wiring for 4~20 mA 3-Wire Sink Operation

Details wiring procedures for the 4-20mA 3-wire sink operation type.

Installation Cable Length Calculation

Explains how to calculate maximum installation cable length based on wire specifications and voltage drop.

GTD-2000 Tx Detector Operation

Initial Status and Self-Test

Describes the display sequence and self-test procedure upon powering on the detector.

Measuring Mode Operation

Explains how the detector displays measurements and indicates alarm conditions in normal operation.

Operational Flow and Mode Navigation

Illustrates the operational flow and navigation between different modes using the device keys.

Menu Configuration Table

Presents a comprehensive table of configurable parameters for various system modes.

GTD-2000 Tx System Mode Configuration

Program Mode Settings

Details settings for the Program Mode, including gas type, units, and high scale configuration.

Calibration Mode Procedures

Outlines the steps for entering and performing calibration modes.

Zero Calibration Process

Explains the step-by-step procedure for performing zero calibration on the detector.

Span Calibration Process

Details the procedure for performing span calibration using standard calibration gas.

Alarm Mode Settings

Covers settings for alarm levels, types, dead bands, and dwell times for alarms.

GTD-2000 Tx Troubleshooting Guide

Fault List and Causes

Lists common fault messages, their descriptions, and potential causes for the detector.

Fault Recovery Solutions

Provides solutions for identified faults, including component replacement and re-calibration.

GTD-2000 Tx Drawings and Dimensions

Standard Type Dimensional Drawing

Presents detailed dimensional drawings for the standard configuration of the GTD-2000Tx.

Drawing with Warning Light Connection

Shows dimensional drawings illustrating the unit with an attached warning light.

Drawing with Raincover Connection

Displays dimensional drawings for the unit when a raincover is installed.

Installation Precautions for GTD-2000 Tx

Installation Site Selection (Safety Act Data)

Provides guidelines for selecting an installation site based on occupational health and safety regulations.

Site Selection for Gas Leakage

Offers advice on site selection considering gas leakage, properties, and ventilation.

Installation Precautions and Environment

Lists important precautions and environmental factors to consider during installation.