Do you have a question about the Gasmet DX4040 and is the answer not in the manual?
Technology | FTIR (Fourier Transform Infrared Spectroscopy) |
---|---|
Measurement Principle | Fourier Transform Infrared Spectroscopy |
Measured Gases | CO, CO2, CH4, NH3, H2O |
Measurement Range | ppm to % levels depending on the gas |
Detection Limit | ppb level |
Response Time | Typically less than 1 minute |
Sampling | Continuous sampling |
Applications | Environmental monitoring, industrial processes, and emission testing |
Gas Cell Temperature | 180 °C (adjustable) |
Gas Cell Path Length | 5 meters or more |
Spectral Range | 900 - 4000 cm-1 |
Resolution | 8 cm-1 |
Detector | MCT (Mercury Cadmium Telluride) |
Measurement Interval | 1 second |
Operating Temperature | +5 … +35 °C |
Power Supply | 100 – 240 VAC, 50/60 Hz |
Guidelines to avoid electrical shock or personal injury when using the analyzer.
Details the items included in the Gasmet DX4040 package.
Overview of the DX-Series, focusing on the DX4040 for on-site measurements.
Explains the physical structure and components of the DX4040.
Details the analyzer's battery and AC/DC power supply unit.
Information on the 120-watt AC/DC power supply unit.
Describes the front panel layout, including fittings, controls, and indicators.
Explains the quick-connect fittings for sample, zero gas, and purge.
Explains the power switch modes and status LEDs.
Information on the provided IP67 PDA and Calcmet Lite software.
Specifies conditions for lifting, carrying, and general operation.
Details AC/DC PSU and battery connection procedures.
Instructions for connecting the AC/DC PSU to power and battery.
Warns against using the equipment in hazardous (EX-rated) areas.
Guides through setting up the computer and PDA for analyser operation.
Lists necessary software and drivers for computer setup.
Instructions for synchronizing data between PDA and computer.
Steps for installing the Calcmet software from the DVD.
Steps for configuring Calcmet software, including COM port and baud rate.
Instructions for checking hardware status and performing zero calibration.
Steps to connect and operate the analyser using Bluetooth.
How to check analyser hardware status using Calcmet Lite.
Procedure for performing zero calibration using nitrogen or dry air.
Options for storing sample spectra, background, and results.
A checklist of key steps for performing measurements.
Important safety warnings before performing maintenance.
Steps for initial inspection to validate warranty.
Instructions for using Li-ion batteries in the analyser.
Information and warnings regarding the laser device in the analyser.