GTC-520A
Instruction Manual
Headquarters / Engineering research laboratory :
23 Gunpo Advance d Industry 1-ro(Bugok-dong), Gunpo-si, Gyeonggi-do
Tel +82-31-490-0800 Fax +82-31-490-0801
Yeongnam business office / Plant :
55 Gonghangap-gil 85beon-gil, Gangseogu, Busan Metropolitan City
Tel +51-973-8518 Fax +51-973-8519
E-mail : info@gastron.com
www.gastron.com
Read in detail for correct use.
Question and Answer IconNeed help?

Do you have a question about the GASTRON GTC-520A and is the answer not in the manual?

GASTRON GTC-520A Specifications

General IconGeneral
BrandGASTRON
ModelGTC-520A
CategoryMeasuring Instruments
LanguageEnglish

Summary

1. Overview

2. Features

3. Specifications

3.1. Basic Specifications

Lists measuring value display, range, alarm indicators, output signals, approvals, interface, option, and warranty details.

3.2. Mechanical Specifications

Details dimensions, weight, mounting type, and body material of the unit.

3.3. Electrical Specifications (Standard Type)

Details input/output voltage, current, relay contact, wiring, and EMC protection.

3.4. Environmental Specifications

Lists operation and storage temperatures, humidity, and pressure range.

4. Name and description of each part

5. Installation

5.1. Configuration of power supply

Explains how to connect the AC power supply to the terminal box and power input.

5.2. Configuration of signal terminal

Details the terminal configuration for 4-20mA output, external reset, and RS485 using CN6.

5.3. Configuration of Relay terminal

Describes the configuration of 3 Alarm relays and 1 Trouble relay using CN5 terminal.

5.4. How to connect 3-wire type Gas detector

Illustrates how to connect a 3-wire gas detector using a 4-20mA output.

5.5. How to connect 2-wire type Gas detector

Explains how to connect a 2-wire gas detector with a 2-wire output.

6. How to operate

6.1. Power ON

Details the initial power-on checks, including wire connections and power LED status.

6.2. Measuring Mode

Explains the display during normal gas measurement, including Undr and oUEr states.

6.3. Test Mode

Describes how to enter Test Mode and use it for checking functions without gas injection.

6.4. Checkup mode (Stand-by Mode)

Explains how to enter Checkup (Stand-by) Mode for self-diagnosis and status checking.

6.5. Setting for operation

6.5.1. Setting Table

A comprehensive table outlining various setting parameters, levels, and default values.

6.5.2. PROGRAM MODE

Details how to set parameters like decimal point, high scale, SAD value, and password.

6.5.3. ALARM Mode

Covers designation of Alarm1, Alarm2, Alarm3 values and related settings.

ALAr (Alarm Mode - Direction)

Mode for setting the operation direction of Alarm1, using 1H or 1L modes based on gas value comparison.

AL-1 (Alarm 1 Value Setting)

Function to change the setting value for Alarm 1, adjustable up to the High Scale value.

IH (Alarm 1 Direction - High)

Mode for setting the operation direction of Alarm1 (larger than or equal to setting value).

IL (Alarm 1 Direction - Low)

Mode for setting the operation direction of Alarm1 (smaller than or equal to setting value).

1H00 (Alarm 1 Dead Band)

Mode for setting the Dead band value for Alarm 1 operation.

1L00 (Alarm 1 Dead Band)

Mode for setting the Dead band value for Alarm 1 operation.

A1rL (Alarm 1 Contact Output)

Function for setting of Alarm 1 contact output.

ON/OFF (Alarm 1 Contact Output)

Mode for change of Alarm 1 contact output, with ON/OFF options affecting operation.

A16L (Alarm 1 Blink Output)

Setting function for Alarm1 blink output, with ON/OFF options.

End (Alarm Mode Completion)

Message indicating completion of setting function before returning to gas concentration display.

6.5.4. Option setting

Covers optional functions, typically factory-set.

OPŁ (Optional Function Setting)

Mode for setting of optional functions, typically factory-set and used with caution.

n-L (Checkup Mode Display Setting)

Mode for display of FND and setting of outputted value in checkup mode.

Undr (Under Function Setting)

Item for setting use status for marking function of Undr in FND for values less than 0.

ON/OFF (Under Function)

ON/OFF state for the Under function, controlling its usage.

En9 (Unprocessed Data Display)

For display of measured value, showing unprocessed data from -XXXX to +YYYY.

ON/OFF (En9 Function)

ON/OFF state for the En9 function, used in test mode.

2-5 (Zero Skip Setting)

Item for setting of Zero Skip, adjusting the value for high scale range.

0 (Zero Skip Setting Value)

Setting is possible within the range of 0-20% using UP/DOWN SW for Zero Skip.

5-5 (Span Skip Setting)

Item for setting of Span Skip, adjusting the value for high scale range.

Eto (Emergency Time Out Setting)

Item for setting of Emergency Time Out, determining status of time setting upon checkup mode.

ON/OFF (Eto Function)

ON/OFF state for Eto function, controlling checkup mode time duration.

End (Option Setting Completion)

Message informing completion of setting function before returning to gas concentration display.

6.5.5. Test Mode

Covers various test modes for functions like detector testing, relays, and mA output.

TEST (Test Mode Function)

Describes the test mode function, allowing arbitrary concentration setting for alarm testing.

TrLY (Trouble Relay Test)

Mode for ON/OFF setting of Trouble Relay Test operation.

ON/OFF (Trouble Relay Test)

ON/OFF state for Trouble Relay Test, enabling or disabling the function.

ArLY (Alarm Relay Test)

Mode for ON/OFF setting of Alarm Relay Test operation.

ON/OFF (Alarm Relay Test)

ON/OFF state for Alarm Relay Test, enabling or disabling the function.

Rout (mA Output Signal Test)

Test Mode for mA Output Signal, enabling testing of mA output.

ON/OFF (mA Output Test)

ON/OFF state for mA Output function, controlling its usage.

Full Range (Output Calibration Test)

Testing Mode for output current after calibration is finished.

6.5.6. 485 Setting Mode

Covers setting for RS485 communication, including channel number and parity bit.

485 (RS485 Function Setting)

Mode for setting of 485 function, enabling communication setup.

CHno (Channel Number Setting)

Setting function for Channel Number to identify Control Unit in communication.

0 (Channel Number Setting)

Channel Number setting mode, allowing unique identification of Control Units.

128 (Channel Number Setting)

Channel Number setting mode, allowing unique identification of Control Units.

PR (Parity Bit Setting)

Mode for setting of Parity Bit for 485 communication.

0 (Parity Bit - NONE/EVEN/ODD)

Setting for Parity Bit, with options for NONE, EVEN, ODD.

2 (Parity Bit - NONE/EVEN/ODD)

Setting for Parity Bit, with options for NONE, EVEN, ODD.

6.5.7. Maintenance Mode

Covers maintenance functions like input/output value reference and current setting.

In (Input Value Reference)

Mode for selection of outputting current input value as reference for Channel Unit.

-out (Output Value Reference)

Mode for selection of outputting output value as reference for Channel Unit.

1804 (mA Input Setting)

Setting mode by inputting of mA current when 'In' has been selected.

4.00 (mA Input Setting)

Setting mode by inputting of mA current when 'In' has been selected.

SUC (Success Indicator)

Indicates success when inputting normal current value during maintenance.

C-F (Calibration Fail Indicator)

Indicates calibration failure when inputting abnormal current value.

1820 (20mA Input Setting)

Setting mode by inputting of 20mA current.

SUC (Success Indicator)

Indicates success when inputting normal current value during maintenance.

C-F (Calibration Fail Indicator)

Indicates calibration failure when inputting abnormal current value.

3.00 (4mA Output Setting)

Next mode for input current when 'out' has been selected, for setting of 4mA output current.

9.99 (4mA Output Setting)

Next mode for input current when 'out' has been selected, for setting of 4mA output current.

10.00 (20mA Output Setting)

Mode for setting of 20mA output current.

30.00 (20mA Output Setting)

Mode for setting of 20mA output current.

End (Maintenance Mode Completion)

Message informing completion of setting function before returning to gas concentration display.

6.5.8. Factory initialization function (Factory Initial)

Initializes product data to factory settings.

F-r (Factory Initialization Mode)

Mode for initialization of the currently saved data to the existing data upon factory shipment.

YES (Enable Factory Initial)

Enables Factory Initial function when selected.

6.5.9. Initialization function for calibration data (Calibration Initial)

Initializes calibration data to product's basic setting value.

1 (Calibration Data Initialization Step 1)

Function using FUNC S/W for consecutive S/W pushing, outputting data for initialization.

1111 (Calibration Data Initialization Step 2)

Function using FUNC S/W for consecutive S/W pushing, outputting data for initialization.

7. Interface configuration

Details interface settings for communication protocols.

7.1. MODBUS RS485

Details interface settings for MODBUS RS485 communication.

7.1.1. Interface setting

Specifies data format, baud rate, data bits, stop bit, and parity for RS485.

7.1.2. MODBUS RS485 Register map

Provides a map of MODBUS RS485 addresses, bits, and descriptions for measured values and states.

8. Outline drawing and Dimensions

7. Revision record

Related product manuals