4. Connect output terminals AC OUT 1, AC OUT 2 to the film.
5. Turn the AC mains ON again.
During this step please make sure the switch is in the neutral position,
otherwise the unit can enter into a latched up state. If something like this
happens remove the AC mains, move the switch to the neutral position
and restore the power supply to the unit.
6. Toggling the switch to the UP position will dim the film to a
transparent state. When releasing the switch, the current transparent state
will be preserved.
7. To dim the film to translucent, toggle the switch to the DOWN state.
Note: The same functionality can be achieved by connecting the DT & DO
terminals to the AC LINE through relays.
Note: Do not close simultaneously more than one dry contact. Operation
under this condition is not guaranteed.
Note: You can also use Gauzy’s Controller Dimming Touch Panel for this
configuration.