Working with the DMX Interface
The Flex controller has 1 channel output. Each data is composed of an 8-bit
word that refers the status of the Flex controller output.
DMX protocol allowing to chain a total of 512 Flex controllers to reside in one
DMX512 link (Universe).
Each Flex is mapped to a dierent DMX address with the designated base
address in the DMX ID, defined in the configuration menu. For example,
If the DMX ID defined is 1, then Flex controller will be mapped to address 1.
If the DMX ID defined is 2, then Flex controller will be mapped to address 2, etc.:
Flex 1 – Address 001
Flex 2 – Address 002
Flex 3 – Address 003
Flex 4 – Address 004
Flex 54 – Address 054
Flex 362 – Address 362
To work in DMX mode, press the reset button on the Flex controller.
Set the Flex controller to DMX Mode by sending the command “G0”
(G-Zero).
Set the Flex address by sending the command “A[xxx]” with the correct
address. For example, address 1 - A001, address 23 – A023, etc.
After configuration is complete, press the reset button on the Flex
controller and verify the configuration is done, or send the command “P”
to see the configuration menu again.
For DMX interface, switch the cable from the PC to the external DMX
controller. After 40 seconds, the device should sync to the DMX link and the
status LED should blink. If not – Send the command “X” and Flex controller will
immediately react to DMX commands.