9
RS485/DMX/COM Control (available on specific models)
Terminal
Name
Terminal
Number
Description
DMX -
IN
D-Type
Pin 2
DMX input connector / RS485 interface.
When installed in a DMX system this is the input connector in
the DMX chain.
DMX -
OUT
D-Type
Pin 3
When installed in a DMX system this is the output connector
in the DMX chain and should be connected to the next device
in-line.
Cascade Interface
Terminal
Name
Terminal
Number
Description
IN 12
Module cascade input.
Connect to CASCADE OUT of the MASTER unit to cascade
multiple devices with a single control.
OUT 14
Module cascade output.
Connect to CASCADE IN of the SLAVE unit to cascade multiple
devices with a single control.
COMMON 13, 15 Common GND terminal. Connect between two cascaded units.
Status Interface
Terminal
Name
Terminal
Number
Description
ALARM 21
Alarm output.
OUT OK 20
Output OK Signal.
COMMON 23 Common GND terminal.
N.C. 24 Not Connected.
Film Interface
Terminal
Name
Terminal
Number
Description
AC OUT1
AC OUT2
18, 19
Film output voltage.
These two terminals should be connected to the film.