1–10 345 TRANSFORMER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
RS485 INTERFACE CHAPTER 1: COMMUNICATIONS GUIDE
2 16-Bit Frozen Counter 1 (read) 22
(assign
class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
129
(response)
00, 01
(start-stop)
17, 28
(index) (see
Note 2)
9 32-Bit Frozen Counter
without Flag
1 (read) 22
(assign
class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
129
(response)
00, 01
(start-stop)
17, 28
(index) (see
Note 2)
10 16-Bit Frozen Counter
without Flag
1 (read) 22
(assign
class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
129
(response)
00, 01
(start-stop)
17, 28
(index) (see
Note 2)
22 0 Counter Change Event
(Variation 0 is used to
request default
variation)
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
--- ---
1 32-Bit Counter Change
Event
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
23 2 16-Bit Counter Change
Event
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
5 32-Bit Counter Change
Event with Time
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
6 16-Bit Counter Change
Event with Time
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
0 Frozen Counter Event
(Variation 0 is used to
request default
variation)
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
--- ---
1 32-Bit Frozen Counter
Event
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
2 16-Bit Frozen Counter
Event
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
5 32-Bit Frozen Counter
Event with Time
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
6 16-Bit Frozen Counter
Event with Time
1 (read) 06 (no range, or all)
07, 08 (limited
quantity)
129
(response)
130 (unsol.
resp.)
17, 28
(index)
30 0 Analog Input (Variation
0 is used to request
default variation)
1 (read) 22
(assign
class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
--- ---
OBJECT REQUEST RESPONSE
OBJECT
NO.
VARIATION
NO.
DESCRIPTION FUNCTION
CODES
(DEC)
QUALIFIER CODES
(HEX)
FUNCTION
CODES
(DEC)
QUALIFIER
CODES
(HEX)

Table of Contents