489
GENERATOR MANAGEMENT RELAY
®
Instruction Manual
489 Firmware Revision: 32H150A8.000
489PC Software Revision: 1.50
Manual P/N: 1601-0071-E8 (GEK-106290)
Copyright © 2002 GE Power Management
GE Power Management
215 Anderson Avenue, Markham, Ontario
Canada L6E 1B3
Tel: (905) 294-6222 Fax: (905) 294-8512
Internet: http://www.GEindustrial.com/pm
Manufactured under an
ISO9001 Registered system.
g
GE Power Managemen
t
808754E3.CDR
489 IN SERVICE BREAKER OPEN R1 TRIP
R2 AUXILIARY
R3 AUXILIARY
R4 AUXILIARY
R5 ALARM
R6 SERVICE
SETPOINT ACCESS
BREAKER CLOSED
COMPUTER RS232
HOT STATOR
MESSAGE
VT FAILURE
BREAKER FAILURE
489 Generator Management Relay
PROGRAM PORT
SETPOINT
7 89
4
5
6
12 3
.
0
HELP
MESSAGE
VALUE
ACTUAL
ESCAPE
ENTER
TM
RESET
NEXT
RESET
POSSIBLE
COMPUTER RS485
AUXILIARY RS485
ALT. SETPOINTS
489 STATUS GENERATOR STATUS OUTPUT RELAYS
NEG. SEQUENCE
GROUND
LOSS OF FIELD
g

Table of Contents

Other manuals for GE 489

Question and Answer IconNeed help?

Do you have a question about the GE 489 and is the answer not in the manual?

GE 489 Specifications

General IconGeneral
BrandGE
Model489
CategoryRelays
LanguageEnglish

Summary

1 INTRODUCTION

1.1 OVERVIEW

Provides an overview of the 489 relay, its features, and general information.

1.2 SPECIFICATIONS

Details technical specifications for the 489 relay, including power supply, inputs, and outputs.

3 OPERATION

3.2 SETPOINT ENTRY

Outlines the procedure for accessing and modifying setpoints via the front panel keypad.

4 SETPOINT PROGRAMMING

6 COMMUNICATIONS

6.1 ELECTRICAL INTERFACE

Details the hardware and electrical interface, including RS485 and RS232 ports and Modbus protocol.

6.3 MEMORY MAP

Provides information on the memory map structure, including register addresses and data formats.

7 TESTING

7.1 TEST SETUP

Outlines the purpose of testing and lists the various tests to be performed on the 489 relay.

8 489PC SOFTWARE

8.1 INSTALLATION/UPGRADE

Provides information on installing, upgrading, and configuring the 489PC software and relay firmware.

APPENDIX A A.1 COMMISSIONING

A.1.1 SETPOINTS SUMMARY

Summarizes default and user-defined setpoints for the 489 relay across various pages.

Table A–1: SETPOINTS PAGE 1 – 489 SETUP

Lists default and user values for 489 SETUP setpoints, including Passcode and Serial Ports.

Table A–3: SETPOINTS PAGE 3 – DIGITAL INPUTS (Sheet 1 of 3)

Lists digital input setpoints for General Inputs A, B, C, and D, including their configurations.

Table A–5: SETPOINTS PAGE 5 – CURRENT ELEMENTS (Sheet 1 of 7)

Lists current element setpoints, covering Overcurrent Alarm, Offline Overcurrent, and Inadvertent Energization.

Table A–6: SETPOINTS PAGE 6 – VOLTAGE ELEMENTS (Sheet 1 of 3)

Lists voltage element setpoints including Undervoltage, Overvoltage, Volts/Hertz, and Underfrequency.

Table A–10: SETPOINTS PAGE 9 – THERMAL MODEL (Sheet 1 of 2)

Lists thermal model setpoints for setup, overload curves, and RTD bias parameters.

APPENDIX B B.1 STATOR GROUND FAULT PROTECTION

B.1.1 DESCRIPTION

Provides general concepts and guidelines for protecting generator stators against ground faults.

B.1.2 NEUTRAL OVERVOLTAGE ELEMENT

Describes the neutral overvoltage element for detecting stator ground faults.

B.1.3 GROUND OVERCURRENT ELEMENT

Details the ground overcurrent element as a replacement or backup for neutral overvoltage.

B.1.4 GROUND DIRECTIONAL ELEMENT

Explains the ground directional element using Vneutral and ground current inputs for fault detection.

B.1.5 THIRD HARMONIC VOLTAGE ELEMENT

Covers the third harmonic voltage element for detecting stator ground faults near the generator neutral.