4 49-7812
USING THE AIR CONDITIONER
Controls
Controls
1. Power Pad
Turns air conditioner on and off. When turned on, the
display will show the room temperature.
2. Display
Shows the room temperature or time remaining on the
Delay timer. Shows the Set temperature while setting
the temperature in Cool or Energy Saver modes.
3. Temp Increase + /Decrease – Pads
8VHWRVHWWHPSHUDWXUHZKHQLQ&RRORU(QHUJ\6DYHU
mode. The Set light will turn on while setting..
4. Delay Increase + /Decrease – Pads
(DFKWRXFKRIWKH,QFUHDVHŸ'HFUHDVHźSDGVRQ
WKHXQLWRUWKH,QFUHDVH'HFUHDVH±SDGVRQWKH
remote control will set the delay time when using the
'HOD\±KUWLPHU7KH6HWOLJKWZLOOWXUQRQZKLOH
setting.
5. Fan Speed Pad
8VHWRVHWWKHIDQVSHHGWR/RZ0HG+LJK
or Auto on the unit. NOTE: On the remote control, use
WKHIDQVSHHG,QFUHDVH'HFUHDVH±SDGVWRVHWWKH
IDQVSHHGVWR/RZ0HGRU+LJK8VHWKH$XWRSDGWR
turn Auto
fan on.
6. M
ode Pad
8VHWRVHWWKHDLUFRQGLWLRQHUWR&RRO(QHUJ\6DYHURU
Fan Only mode.
7. Delay Pad
Delay ON—When the air conditioner is off, it can be
set to automatically come on in 1 to 24 hours at its
previous mode and fan settings.
Delay OFF—When the air conditioner is on,
it can be set to automatically turn off in 1 to
24 hours.
How to set:
3UHVVWKH'HOD\±KUSDGRQWKHXQLWRUWKH'HOD\
pad on the remote control. Each touch of the Increase
Ÿ'HFUHDVHźSDGVRQWKHXQLWRUWKH,QFUHDVH
'HFUHDVH±SDGVRQWKHUHPRWHFRQWUROZLOOVHWWKH
timer in 1-hour intervals. The Set light will turn on while
setting.
7RUHYLHZWKHUHPDLQLQJWLPHRQWKH'HOD\±KU
WLPHUSUHVVWKH'HOD\±KUSDGRQWKHXQLWRUWKH
'HOD\SDGRQWKHUHPRWHFRQWURO8VHWKH,QFUHDVH
Ÿ'HFUHDVHźSDGVRQWKHXQLWRUWKH,QFUHDVH
'HFUHDVH±SDGVRQWKHUHPRWHFRQWUROWRVHWDQHZ
time if desired.
7RFDQFHOWKHWLPHUSUHVVWKH'HOD\±KUSDGXQWLO
WKHOLJKWRQWKH'HOD\±KUSDGJRHVRII
8. Filter Reset Pad
/('ZLOOWXUQRQZKHQIDQKDVDFFXPXODWHGKRXUV
of run time as a reminder to clean filter. Press Reset
)LOWHUWRWXUQRIIWKH/('DQGUHVHWWKHDFFXPXODWHGUXQ
time.
Features and appearance will vary.
/LJKWVEHORZWKHWRXFKSDGVRQWKHDLUFRQGLWLRQHUFRQWUROSDQHOLQGLFDWHWKHVHOHFWHGVHWWLQJV
Air Conditioner Controls
Remote Control
Fan Fan
Delay
±KU
Delay timer
Decrease
Mode select
Fan speed
Decrease
Temperature
set Increase
and
Decrease
Delay
timer
Increase
Auto Fan
on
Fan speed
Increase
8QLWSRZHU
RQRII
NOTE: The display always shows the room temperature
H[FHSWZKHQsetting the Set temperature or the Delay timer.
Power
On/Off
Fan Mode
Auto
Reset
Filter
High
Med
Low
Cool
Fan Only
Energy Saver
Delay
1-24 Hrs
Set
+
-
8
/LJKWLQGLFDWHVWKH
delay timer is set.
/LJKWLQGLFDWHVWKHXQLWLVLQWKH
temperature or delay time Set mode.
Note: The default temperature reading on the display is degree Fahrenheit ( °F). To change the
display to degree Celsius (°C), press the Temp Increase Ÿ and Temp Decrease ź buttons together
and hold for 3 seconds. Repeat the process to change back to degree Fahrenheit (°F)