Do you have a question about the GE ATS1340 and is the answer not in the manual?
The ATS1340 is a universal door junction box designed to integrate access control and alarm functionalities for doors. It provides a robust solution for connecting various door-related components to an Advisor MASTER bus reader or a panel/DGP (Data Gathering Panel).
The primary function of the ATS1340 is to act as an interface between a door's access control components and the main security system. It features incoming and outgoing data bus/power connections (J1 and J12 respectively) to ensure proper stub connection for an Advisor MASTER bus reader.
Onboard relays (RL1 and RL3) are provided for connecting a door lock and auxiliary outputs, such as a buzzer. For high-energy door locks, an external 12 V or 24 V power supply must be connected to J2.
The module includes two onboard dual loop resistor input configurations (J3) for connecting magnetic switches on the door and the switch in the door lock. These connections can be easily hardwired to the nearest DGP or panel zones.
The ATS1340 also allows for full wiring of an Advisor MASTER bus reader to its terminal strip J9 and provides connections for a request-to-exit (RTE) button (J6).
Supply Voltage:
Current Consumption:
Output Current:
Environmental:
Physical:
Connections:
Mounting: The ATS1340 PCB can be mounted in any Advisor MASTER cabinet that supports a size B board. It is recommended to mount the door junction box in close proximity to the door it controls. To mount the unit:
Wiring:
Jumper Configurations:
Power Disconnection: Before opening the cabinet or working on the device, it is crucial to disconnect the mains power. This can be done by unplugging the AC mains plug from the wall socket or by disconnecting the mains with a dedicated circuit breaker. If applicable, disconnect the battery as well.
Fuse Protection: Fuse FH1 protects the bus +12V if this power supply is used for external connections (J9-6 / J8-4). FH2 protects the connection to the buzzer (630 mA).
LED Status Indicators:
Wiring Recommendations: Use CAT 5 cable as described in the manuals for connected devices. The bus cable must be grounded.
WEEE Compliance: The device is marked with the WEEE symbol, indicating that it should not be disposed of in European public disposal systems. European users are required to return end-of-life equipment for proper disposal. Further information is available on www.recyclethis.info.