Performance Data Sheet o,Ts0nTen70 e,s
SmortWater Filtration Sgstem-GE®IVlWFCartridge
This sgstem has been tested and certified in filter model GE HWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below, The
concentration of the indicated substances in water entering the sgstem was reduced to a concentration less than or equal to the permissible limit for water
leaving the sgstem, as specified in NSF/ANSI Standards 42 and 53,* (Safetg factors built in for unmetered usage)
Standard No. 42: Aesthetic effects
Substance [NSFSpecifiedChallenge _AverageProduct Max Permissible Produc. t] NSFReduction NSFTest
Reduction IAverage Influent I Concentration I Reduction I Water Concentration IWater Concentration I Requirements Report
Standard No. 53: Health effects
Substance I Average Product Max Permissible Prod_
Reduction Average Influent Water Concentration Water Concentration
147,5000 cysts/L cyst/L NiA
47 MF/L <1 MF/L NiA
0.016 mg/L
0.08 mg/L
0.006 mg/L
0,152 mg/L
0,148 mg/L
O.O058mg/L
0.0061 mg/L
O,222mg/L
O,015mg/L
NSFSpecified Chal!enge
Concentration
Minimum 50,000 cysts/L
lotto ldfibers/L; fibers
greater than 10 pm in lengt
_L_+10%
0,015 mg/L _+10%
0,08 mg/L _+10%
0,006 mg/L _+10%
0,15 mg/L_+ 10%
0,15 mg/L_+ 10%
0,006 mg/L _+10%
0,006 mg/L _+10%
0,225 mg/L_+ 10%
0,015 mg/L_+ 10%
0,218 mg/L 0210 mg/L_+ 10%
*Based on the use of Cryptosporidium parvu m oocysts
Capacity 300 gallons (1,135 liters). Contaminant reduction determined by NSFtesting.
Application Guidelines/Water Supply Parameters
Service Flow
Water Supply
O,O005mg/L
0,001 mg/L
O,O003mg/L
0,001 mg/L
0,001 mg/L
0,005 mg/L
0,04 mg/L
0,002 mg/L
0,010 mg/L
0,010 mg/L
0,0004 mg/L 0,002 mg/L
0,0004 mg/L 0,002 mg/L
0,005 mg/L 0,075 mg/L
0,0005 mg/L 0,005 mg/L
0,0009 mg/L 0,07 mg/L
NSFReduction NSFTest
Requirements Report
_99,95% J-00077721
_99% J-00077707
NiA J-00077708
NiA J-00077717
NiA J-00077718
N/A J-00082185
N/A J-00077722
N/A J-00077723
N/A J-00077726
N/A J-00077727
N/A J-00077728
N/A J-00077729
N/A J-00082184
N/A J-00077730
NiA J-00077705
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Operating Specifications
• Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
• Temperature: ]]-IO0°F (0.6-]8°C)
• Flow rate: 0.5 gpm (1.9Ipm)
General Installation/Operation/Maintenance Requirements
• Flush new cartridge at full flow for 1-1/2 gallons (about three minutes) to purge
trapped air.
• Replace cartridge when flow becomes too stow.
• Protect from freezing by removing filter cartridge when temperatures ore
expected to drop below 33°F (1°C).Do not install sgstems in areas where
ambient temperatures mag go above IO0°F or below 40°E Do not install
on a hot water supplg.
Special Notices
• installation instructions are included with the product when shipped.
• This drinking water sgstem must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
• Do not use with water that ismicrobiologically unsafe or of unknown qualitg
without adequate disinfection before or after the system. Systems certified for
cyst reduction may be used on disinfected water that may contain filterable cysts.
• The contaminants or other substances removed or reduced by this water
treatment system are not necessarily in your water.
• Check for compliance with the applicable state and local laws and regulations.
• Note that while the testing was performed under standard laboratory conditions,
actual performance may vary. Systems must be installed and operated in
accordance with manufacturer's recommended procedures and guidelines.
• Installation and use MUSTcomply with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPa), you should install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
• Where a backflow prevention device isinstalled on a water system, a device for
controlling pressure due to thermal expansion must be installed.
Tested and Certified bg NSF International against ANSI/NSF Standards 42 and 55 in model GE MWF for the reduction off
Standard No. 42: Aesthetic Effects
• Chemical
- Chlorine Taste and Odor
• Mechanical Filtration
- Particulate Reduction, Class I
GE
Appliances
Appliance Park
Louisville, KY40225
geapplianceparts.com
Standard No. 53: Health Effects
• Chemical Reduction
- Atrazine Reduction
- Endrin Reduction
- Benzene and Carbofuran Reduction
- 1,4 Dichlorobenzene and
2,4-D Reduction
- Lead and Lindane Reduction
- Hercurg and Toxaphene Reduction
• Mechanical Filtration
- Cyst and Asbestos Reduction
REPLACEN ENT
ELEHENT
© 2010 GE Compang PC61278B
]5