Performance Data Sheet
SmartWatei Filtration System-GE MWF Cartridge
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53, System tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below,
Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined
S bstanceTe ted i
u s NSFspecified Avg_
for Reduction Average Influent Challenge Concentration Reduction
2.0 mg/L 2.0 mg/L ± 10% 97.5%
7,833,333 pts/mL 99.7%
101,000 cysts/L 99.99%
47 MF/L
0.009 mg/L
0.016 mg/L
0.08 mg/L
0.007 mg/L
0.152 mg/L
0.148 mg/L
0.002 mg/L
0.0058 mg/L
0.0061 mg/L
0.222 mg/L
0.015 mg/L
0.015 mg/L
0.218 mg/L
Based on the use of Cryptosporidium parvum oocysts,
At least 10,000 particles/mL
Minimum 50,000 cysts/L
107 to 108 fibers/L; fibers
greater than 10 pm in length
0.009 mg/L ± 10%
0.015 mg/L ± 10%5
0.08 mg/L ± 10%
0.006 mg/L ± 10%
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.002 mg/L ± 10%
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.225 rag/L± 10%
0.015 rag/L± 10%
0.015 rag/L± 10%
0.210 mg/L ± 10%
>99%
94.5%
96.7%
98.7%
97.1%
99.3%
99.3%
99.0%
93.2%
93.2%
99.8%
96.7%
93.2%
99.5%
_y NSF testing.
Average Product
Water
Concentration
0.05 mg/L
18,617 pts/mL
1 cyst/L
<1 MF/L
0.0005 mg/L
0.0005 mg/L
0.001 mg/L
0.0002 mg/L
0.001 mg/L
0.001 mg/L
0.00002 mg/L
0.0004 mg/L
0.0004 mg/L
0.005 mg/L
0.0005 mg/L
0.001 mg/L
0.0009 mg/L
Ma× Permissible I I
Product Water NSF Reduction NSF
Concentration
N/A
N/A
N/A
N/A
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.002 mg/L
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.002 mg/L
0.002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
0.07 mg/L
Requirements
>-50%
>-85%
>-99.95%
>-99%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Test Report
J-00077703
J-00077704
J-00100036
J-00077707
J-00077708
J-00077717
J-00077718
J-00100039
J-00077722
J-00077723
J-00077726
J-00100037
J-00092355
J-00077729
J-00082184
J-00077730
J-00085470
The following pharmaceutical reduction claims have not been certified by NSF International or the state of California,
Claims tested and verified by independent laboratory:
Reduction
Average Inlluent
978 ng/L
907 ng/I
885 ng/L
1097 ng/L
415 ng/L
ChallengeConcentration
N/A
N/A
N/A
N/A
N/A
Reduction
99.5%
99.4%
94.1%
99.5%
99.5%
AverageProduct
Water
Concentration
5.0 ng/L
5.4 ng/L
52.3 ng/L
5.0 ng/L
2.0 ng/L
MaxPermissible
ProductWater
Concentration
N/A
N/A
N/A
N/A
N/A
I
NSEReduction NSF
Requirements Test Report
N/A J-00121587
N/A J-00121587
N/A J-00121588
N/A J-00121589
N/A J-O0121587
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (21.9 Ipm)
Water Su_p!y Potable Water
Water Pressure 40-120 psi (2.8-8.2 bar)
Water Temperature 33°F-100°F (0.6°C-38°C)
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note: While the testing was performed under standard laboratory corlditions,
actual performance may vary,
Replacement Cartridge: MWF, For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www,geapplianceparts,com,
_WARNING
To reduce the risk associated with ingestion of contaminants:
. Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certified
for cyst reduction may be used on disirffected water that may contain filterable
cysts, EPA Establishment Number 10350-MN-005,
For corlditions of use, health claims certified by the California Department of Public
Health, and replacements, see performance data sheet, California Department
of Public Health Certification #05-1698, The corltamirlants or other substances
removed or reduced by this water filter are not necessarily in all users' water,
NOTICE
To reduce the risk associated with property damage due to water leakage:
. Read and follow use instructions before installation and use of this system.
Installation and use MUST comply with all state and local plumbing codes,
Do not install ifwater pressure exceeds 120 psi (8,2 bar), If your water pressure
exceeds 80 psi, you must install a pressure-limiting valve, Contact a plumbing
professional if you are uncertain how to check your water pressure,
Do not install where water hammer conditions may occur, Ifwater hammer
conditions exist you must install a water hammer arrester, Contact a plumbing
professional if you are uncertain how to check for this condition,
Do not install on hot water supply lines, The maximum operating water
temperature of this filter system is 100 ° F (38° C).
. Protect filter from freezing. Drain filter when temperatures drop
below 33°F (0,6°C),
, The disposable filter cartridge must be replaced every 6 months at the
rated capacity, or sooner if a noticeable reduction in flow rate occurs,
REPLACEMENT
ELEMENT
Jested and cprbfied by NSF International
against NSF/ANS] Standard 42 and
Standald 53in model GEMWF tur the
reduction of the claims specified on the
i_ltormarlcp data sheet
41