5
Installation Instructions
GAS REQUIREMENTS
DRYER GAS SUPPLY CONNECTION
GAS SUPPLY
•  A 1/8” National Pipe Taper thread plugged 
tapping, accessible for test gauge connection, 
must be installed immediately upstream of the 
gas supply connection to the dryer. Contact your 
local gas utility should you have questions on the 
installation of the plugged tapping.
•  Supply line is to be 1/2” rigid pipe and equipped 
with an accessible shutoff within 6 feet of, and in 
the same room with, the dryer.
•  Use pipe thread compound appropriate for 
natural or LP gas or use PTFE tape.
•  Connect flexible metal connector to dryer and 
gas supply.
ADJUSTING FOR ELEVATION
•  Gas  clothes  dryers  input  ratings  are  based  on 
sea  level  operation  and  need  not  be  adjusted 
for  operation  at  or  below  2000  ft.  elevation.  For 
operation  at  elevations  above  2000  ft.,  input 
ratings should be reduced at a  rate  of  4  percent 
for each 1000 ft. above sea level. 
•  Installation  must  conform  to  local  codes  and 
ordinances  or,  in  their  absence,  the  NATIONAL 
FUEL GAS CODE, ANSI Z223.
You must use with this dryer a flexible metal connector 
(listed connector ANSI Z21.24 / CSA 6.10). The length 
of the connect shall not exceed 4 ft.
• Use a new CSA International approved flexible 
gas supply line. Never reuse old flexible 
connectors.
• Install an individual manual shut-off valve 
within 6ft. of the dryer in accordance with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 
54.
• Securely tighten all gas connections.
• If connected to LP gas, have a qualified 
person make sure gas pressure DOES NOT 
exceed 13” water column.
• Examples of a qualified person include: 
licensed heating personnel, authorized gas 
company personnel, and authorized service 
personnel.
• Failure to do so can result in death, 
explosion, or fire.
•  The installation must conform with local 
codes, or in the absence of local codes, with 
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane 
Installation Code, CSA B149.1.
FOR USE WITH NATURAL GAS ONLY
Dryer as produced by manufacturer is to be used 
only with a natural gas supply. A manufacturer-
supplied conversion kit is required to convert 
this dryer for propane gas supply. Use propane 
gas conversion kit WE25M73 for 24” models or 
WE25M74 for 27” models. Conversion must be 
made by properly trained and qualified personnel 
in accordance with local codes and ordinances.
- Fire Hazard
WARNING
-  Explosion Hazard
WARNING