EasyManuals Logo

GE PFE29PS User Manual

GE PFE29PS
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
– 27 –
There are 2 modes of operation for water dispense,
Precise Fill and Auto Fill.
By selecting Precise Fill, the customer can select the
amount of water.
About Precise Fill Options
When using Auto Fill, if a container is not placed
in the dispenser, Auto Fill will not operate, and the
display will notify the consumer.
By selecting Auto Fill, the dispenser will function by
the use of 4 ultrasonic sensors (2 sensors located
below the base of the paddle and 2 sensors located
in front of the dispenser funnel). These sensors
measure the height, width, volume, and shape
of the container and will automatically ll the
container to approximately
90% full*.
Ultrasonic sensors work in much the same way as
backup sensors used on many automobiles.
This system is operated by the LCD control and the
door control board.
(Continued next page)
*Typical ll level is approximately 80%, but will vary
based on the height of the container. Typical range
is 70% to 95%. If the container is over 7.5 inches tall,
the ll level could be anything UP TO 90%.