– 28 –
PFE29 Auto Fill Diagnostic Procedure
To enter sensor diagnostic:
1. Wake the screen.
2. Simultaneously press and hold the Water,
Cubed, and Precise Fill buttons for 5 seconds.
The display on the upper right should show the
status of the sensors.
The rst display shows the dispenser in Sleep mode.
Place a cup in the recess, the display will then show
Cup Presence, Lip Detect, Level Trac wait, and then
go back to sleep when the container is removed.
If there is a lower sensor failure, the display will not
detect the container.
If the display cycles thru these test messages,
the sensors are OK. If the Auto Fill display quickly
displays between Cup Presence and Lip Detect, the
upper sensors have failed and need to be replaced.
Press Auto Fill button to begin dispensing water and
the LCD will display the amount.
To exit sensor diagnostic:
1. Enter service mode by simultaneously pressing
Water, Cubed, and Crushed buttons for 5
seconds.
2. Select Yes.
3. Once in service mode, use code 00-16 to
reboot the refrigerator. (See
Service Diagnostic
Functions
.)
Sleep
Cup Presence
Lip Detect
Level Trac wait
(Continued next page)