About the water softening system.
14
Service: Timer/Water Softening System, Service Checkout Procedure
If you are not getting soft water, and an error code is not displayed,
use the procedures below to find the problem. First make the
following visual checks.
VISUAL CHECKS:
Is there electrical power to the outlet the water
softening system transformer is plugged into?
Is there sufficient salt in the storage tank?
Is the plumbing bypass valve directing water
for soft water service?
Is the valve drain hose open to the drain, not
elevated too high, and unobstructed?
If you do not find a problem with the visual checks,
continue below.
4
3
2
1
NO SOFT
WATER
TIMER SHOWS WRONG
TIME AND DAY, AND/OR
FLASHING.
TIMER DISPLAY
BLANK.
TIMER DISPLAY SHOWS CORRECT
TIME AND DAY AND IS STEADY.
Check electrical power to
timer (outlet, transformer,
power cable, all connections).
Do manual
diagnostics.
NO POWER
POWER OK
REPAIR AS
NEEDED
TIMER
DEFECTIVE
Do manual
diagnostics to
verify proper
function.
Electrical power was off.
Reset the correct time of
day.
Investigate reason for power loss.