VI. Maintenance
Daily:
Check for any unusual noise, failure to build vacuum, overheating, vibration and correct
before damage of a serious nature can develop.
Check and add oil to vacuum pump reservoir, if necessary. The “U” shaped hose on the
reservoir acts as a sight glass. Oil level should be ¾ of the way up the hose.
Flush and clean storage tank after daily use.
Unit should be stored indoors in a clean, dry location.
Check and clean strainer. Remove the strainer basket and it is free of debris or sludge.
Replace the basket if needed.
Weekly:
Keep compressor clean for efficient operation.
Monthly:
Check and tighten all bolts as required. Check air connections and joints for leaks –
tighten if necessary.
As required:
If vacuum level drops below 10”Hg it may be necessary to flush the vacuum head. Please
follow the procedure found on page 13.
-7-