Display Telephone List? (For GEM-P9600/3200 panels only) (OPTIONAL--Phone Numbers Pro-
grammed? YES NO) The panel can dial any of four programmed telephone numbers.
Select Telephone #1-4 using the NEXT and PRIOR buttons. Press U, then pick up the phone
to automatically dial the displayed number.
Display System Troubles? (For GEM-P9600/3200 panels only) Displays a 2-digit error code
(EXX-NN) representing the problem (XX) detected in the system, followed by 2 digits (NN)
identifying the problem zone, keypad, module, etc. (See SYSTEM TROUBLE ERROR
CODES for a description of these codes). Use NEXT and PRIOR buttons to scroll system
troubles.
Display Fire Alarms? (For GEM-P9600/3200 panels only) Displays alarms that have occurred on
the Fire Zone(s). Press the NEXT and PRIOR buttons to scroll zones.
Display Fire Troubles? (For GEM-P9600/3200 panels only) Displays trouble conditions that have
been detected on the Fire Zone(s). Use NEXT and PRIOR to scroll fire troubles.
Activate Overview? (For GEM-P9600/3200 panels only) (OPTIONAL) (Overview programmed
for user? YES NO)
In a partitioned system, this mode displays the status of Areas 1 and 2 simultaneously. (The
“READY1” display will be replace by the “OV(--)” display shown at left). For each area: “R” =
Area Ready; “z” = Zone Fault; “A” = Area Armed; “B” Burglary Zone in Alarm; “F” Fire Zone in
Alarm; “T” = Fire Trouble; "c” = Check Trouble; Area in Function-Display Mode.
In this mode, all areas (except the area that you are in) may be armed by pressing 9. G,
then entering a valid User Code. (The User Code must be valid in all areas). Similarly, all ar-
eas may be disarmed by pressing
0, G, then entering a valid User Code. To revert
to normal keypad operation, enter a valid code, press
R repeatedly until "TrnOff O View"
appears, then press the YES (
P) button.
FUNCTION MENU
AC ON
DspTel/List/
Yes/No
AC ON
DspSys/Trbl/
Yes/No
reset FIRE ALARM
AC ON
DspFir/Alarm/
Yes/No
TROUBLE
AC ON
DspFir/Trbl/
Yes/No
AC ON
TurnOn/O view
Yes/No
AC ON
OV(RZ)