EasyManua.ls Logo

Gemo AR2-S-24VDC-MB1 - User Manual

Default Icon
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GEMO
AR2 MODBUS GATEWAY AR2-S-24VDC-MB1
SYMBOLS
Attention, High Voltage, Double / NOT CE Mark
Risk of Danger, Risk of Reinforced Litter
Warning Electric Shock Insulation
PRODUCT DESCRIPTION
This device is designed for basic automatic control applications.
Free of charge Ladder Logic Editor with GUI running on PC, “GEMO LADDER EDITOR”;
programming, simulation, download.
2 independent RS-485 communication ports
Connects to AR2 AR2 RS-485 communication line
Connects to MODBUS RS-485 line as a slave
Supported MODBUS protocols; only MODBUS RTU on a RS-485 line
Selectable communication speed for MODBUS connection
Selectable “Parity/Stop Bit” for MODBUS connection
Selectable slave address on MODBUS line
Data security on MODBUS line; selectable “Read” permission
Data security on MODBUS line; selectable “Write” permission
Selectable response delay; adaptable to slow/non-real time masters
LEDs on front panel; ability to monitor communication status
Loads communication parameters automatically from AR2; no extra/special user adjustment
Selectable internal line termination for MODBUS line for easy commissioning
Wide range isolated supply input;18..32VDC
RS-485 CONNECTION
AR2-S-24VDC-MB1 has a selectable internal line termination for MODBUS line for easy commissioning that
can be activated easily with en external bridge connection. Please consult to the following documentation for
line termination details advised for a MODBUS RS-485 line;
“MODBUS over Serial Line Specification & Implementation guide V1.0, MODBUS.ORG, 12/02/02,
http://www.modbus.org/docs/Modbus_over_serial_line_V1.pdf”
Gürbüzoğlu Elektronik San.ve Tic.Ltd.Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: info@gemo.com.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
1
Question and Answer IconNeed help?

Do you have a question about the Gemo AR2-S-24VDC-MB1 and is the answer not in the manual?

Summary

Product Description

RS-485 Connection

Installation, Use and Warnings

General Safety and Usage Precautions

Covers safety, installation, usage, and environmental warnings for the device.

Cleaning Instructions

Guidelines for cleaning the device using appropriate materials and methods.

Technical Specifications

Activation of Internal Line Termination Circuitry

Internal Line Termination Circuitry

Gemo AR2-S-24VDC-MB1 Specifications

General IconGeneral
Supply Voltage24V DC
CommunicationModbus RTU
TypeGateway
ModelAR2-S-24VDC-MB1
BrandGemo