All NPT threads should be installed using a suitable thread sealant (Teflon
tape or Permatex “No more Leaks”). Sealant must be kept out of unit
during installation. Ten diameters of straight run piping are recommended
upstream and downstream of the flow sensor.
The FS-380 end fitting is threaded to the body at assembly and torqued to
25 Ft. Lbs. If disassembly from a system is required, it is advisable to hold
the end fitting hex with a wrench to prevent sensor disassembly. If the
sensor should become disassembled as a result of uninstalling, retorque
the end fitting to 25 Ft. Lbs.
End Fitting
Outlet
Inlet
Spring
Body
FS-380 Flow Switches Can be MountedFS-380 Flow Switches Can be Mounted
FS-380 Flow Switches Can be MountedFS-380 Flow Switches Can be Mounted
FS-380 Flow Switches Can be Mounted
In VIn V
In VIn V
In V
arious Positionsarious Positions
arious Positionsarious Positions
arious Positions
Flow settings are based on a vertical
position (inlet port down), using water at
+70°F on increasing flow. Some variation
in set point actuation will occur in other
mounting orientations.
SpecificationsSpecifications
SpecificationsSpecifications
Specifications
WW
WW
W
etted Materialsetted Materials
etted Materialsetted Materials
etted Materials
Housing
Piston
Spring
O-RingO-Ring
O-RingO-Ring
O-Ring
OperOper
OperOper
Oper
. Pressure, Max.. Pressure, Max.
. Pressure, Max.. Pressure, Max.
. Pressure, Max.
Operating TOperating T
Operating TOperating T
Operating T
emperatureemperature
emperatureemperature
emperature
Required FiltrationRequired Filtration
Required FiltrationRequired Filtration
Required Filtration
Set Point AccuracySet Point Accuracy
Set Point AccuracySet Point Accuracy
Set Point Accuracy
Set Point DifferentialSet Point Differential
Set Point DifferentialSet Point Differential
Set Point Differential
Switch, See “Switch Ratings”Switch, See “Switch Ratings”
Switch, See “Switch Ratings”Switch, See “Switch Ratings”
Switch, See “Switch Ratings”
Inlet / OutletInlet / Outlet
Inlet / OutletInlet / Outlet
Inlet / Outlet
Electrical TElectrical T
Electrical TElectrical T
Electrical T
erminationermination
erminationermination
ermination
Brass or Stainless Steel
PPS Composite
316 Stainless Steel
Fluorcarbon
1500 PSI
-20°F to +275°F (120°C), (-28.8°C to +135°C)
100 Micron or Better
±20%, Maximum
20% Maximum
SPST, 20 VA
3/8 NPT Male
No. 22 AWG, 24 to 26 Polymeric Leads
VA
Volts
0-30
120
240
Amps AC
.4
.17
.08
Amps DC
.3
.13
.06
20
Switch RatingsSwitch Ratings
Switch RatingsSwitch Ratings
Switch Ratings
Max. Resistive LoadMax. Resistive Load
Max. Resistive LoadMax. Resistive Load
Max. Resistive Load
WW
WW
W
iring Diagramiring Diagram
iring Diagramiring Diagram
iring Diagram
Normally Open
0 1 2 3 4 5 6 7
14
12
10
8
6
4
2
0
Spring
170342
Spring
10397
PSI DropPSI Drop
PSI DropPSI Drop
PSI Drop
Pressure Drop - TPressure Drop - T
Pressure Drop - TPressure Drop - T
Pressure Drop - T
ypicalypical
ypicalypical
ypical
Flow Rate - GPMFlow Rate - GPM
Flow Rate - GPMFlow Rate - GPM
Flow Rate - GPM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gems Sensors FS-380 Series and is the answer not in the manual?

Gems Sensors FS-380 Series Specifications

General IconGeneral
BrandGems Sensors
ModelFS-380 Series
CategorySwitch
LanguageEnglish