Thermostat Controls Overview

Screen Illumination

The thermostat screen illuminates for 12 seconds when any button is pressed.

Display Information

Setpoint Indicator

Appears on the screen when the setpoint temperature is displayed.

Low-Battery Warning

Indicates when the thermostat batteries need to be replaced.

System Status Indicators

Shows current operating status like cooling, heating, or auxiliary heat activation.

Ambient and Setpoint Temperature Display

Displays the measured ambient temperature and the setpoint temperature.

System Switch Operation

Operating Modes

Details the Cool, Off, Heat, and Em Heat system operating modes.

Cooling Mode Caution

Warning against using cooling mode when outdoor temperature is below 50°F (10°C).

Fan Switch Operation

Fan Auto Mode

The fan runs only when heating or cooling is taking place.

Fan On Mode

The fan runs continuously for improved air circulation or cleaning.

Temperature Adjustment

Displaying Setpoint Temperature

Press adjustment buttons to display the setpoint temperature for five seconds.

Changing Setpoint Temperature

Press adjustment buttons while setpoint is displayed to change the value.

Battery Replacement

Battery Requirement Note

Batteries are not needed if the thermostat is connected to 24 VAC.

Battery Replacement Procedure

Set system to Off, then install two fresh AAA batteries.

Low-Battery Indicator and Behavior

System operation is disabled if batteries are not replaced within 60 days.

Troubleshooting Common Issues

Blank Screen Resolution

Check circuit breaker, power, furnace door, and battery installation.

Flashing Heat;Cool On Indicator

Indicates compressor protection delay; wait for the compressor to start.

HI or LO Temperature Display

Thermostat disabled due to extreme ambient temperatures (above 122°F or below 32°F).

Advanced Troubleshooting and Settings

E1;E2 Error Code Interpretation

Indicates thermostat disabled due to temperature sensor circuit issues.

Unchangeable Temperature Settings

Occurs when the system switch is set to Off.

Temperature Display vs. Control Limits

Explains display limits (99°F) versus control limits (122°F).