L
W
H
L
W
H
L
W
H
L
W
H
OPEN SET
RUN TIME HOURS USABLE CAPACITY (GAL) L W H WT dBA*
NO TANK - 136 58 68 6088
89
9 183 136 58 81 7036
22 438 136 58 93 7348
35 693 136 58 105 7651
48 946 208 58 108 9295
67 1325 278 58 108 10128
72 1325 278 54 99 9056
WEATHERPROOF ENCLOSURE
RUN TIME HOURS USABLE CAPACITY (GAL) L W H WT dBA*
NO TANK - 175 58 78 8106
84
9 183 175 58 91 9054
22 438 175 58 103 9366
35 693 175 58 115 9669
48 946 208 58 118 11313
67 1325 278 58 118 12146
72 1325 278 54 111 10356
LEVEL 1 SOUND ENCLOSURE
RUN TIME HOURS USABLE CAPACITY (GAL) L W H WT dBA*
NO TANK - 200 58 78 8479
78
9 183 200 58 91 9427
22 438 200 58 103 9739
35 693 200 58 115 10042
48 946 234 58 118 11686
67 1325 304 58 118 12519
72 1325 304 54 111 10860
LEVEL 2 SOUND ENCLOSURE
RUN TIME HOURS USABLE CAPACITY (GAL) L W H WT dBA*
NO TANK - 181 58 107 7988
75
9 183 181 58 120 8936
22 438 181 58 132 9248
35 693 181 58 144 9551
48 946 208 58 147 11195
67 1325 278 58 147 12028
72 1325 278 54 132 10703
Tank Options
MDEQ OPT
Florida DERM/DEP OPT
Chicago Fire Code OPT
IFC Certification CALL
ULC CALL
Other Custom Options Available from your Generac Industrial Power Dealer
* All measurements are approximate and for estimation purposes only. Weights are without fuel in tank. Sound levels measured at 23ft (7m) and does not account for ambient site conditions.
5 of 5
SD275 dimensions, weights and sound levels
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
©2011 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0185610SBY-C / Printed in U.S.A. 09/15/11
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings.
275 kW Diesel