EasyManuals Logo

Genesis BYC-007TG1 User Manual

Genesis BYC-007TG1
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
- 24 -
HE4
Fault code history
Pr
Protocol version
Sr
Software version
2.2 User parameter checking
Press“mode”button 3 seconds to enter parameter checking status, then press “+”or“-”to select parameter.
Parameter
description
range
default
L0
heating
20℃~60
26
L1
Adjustment of temperature difference
before restart
2℃~18
2
L2
Adjustment of temperature difference
before stop
2℃~18
2
L3
cooling
2℃~30
12
L4
Adjustment of temperature difference
before restart when cooling
2℃~18
2
L5
Adjustment of temperature difference
before stop when cooling
2℃~18
2
L6
Set temperature at Auto mode
8℃~60
26
L7
water pump mode
0: water pump always running
1: water pump will stop 60S after
compressor stop, then run 5 min
every(L8)min
0
L8
water pump run 5min every(L8)min
3180min
30